MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14764170802612976

Медицинская библиотека · Journal of cosmetic and laser therapy : official publication of the European Society for Laser Dermatology · 2009

Efficacy and safety of a 0.65 millisecond pulsed portable ND:YAG laser for hair removal.

Khatri Khalil A, Lee Robert A, Goldberg Lynne J, Khatri Beejul, Garcia Veronica

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Based upon the thermal relaxation time of the hair follicle (10-50 ms), most lasers and light devices use relatively long pulse widths for hair removal. This study was conducted to evaluate a shorter pulsed, 0.65 ms Nd:YAG laser for hair removal.

METHODS

One half of each axilla of six female participants was treated and the other half was monitored as a control. The treatment sites were treated with a fluence of either 21 J/cm(2) or 36 J/cm(2) using an Nd:YAG laser with a wavelength of 1064 nm and a pulse duration of 0.65 ms. A manual hair count was done before treatment and at each follow-up visit.

RESULTS

Four months after four monthly treatments, the hair reduction was graded as 5 (75-100% reduction) on the high fluence side and 4 on the low fluence side (50-75% reduction) by individuals and investigators. The average hair count 4 months after four treatments in the sites treated with a high fluence went from 114 to 28 (76% reduction) and in the low fluence areas from 135 to 38 (72% reduction).

CONCLUSION

This well-controlled study shows that a 0.65 ms Nd:YAG laser is effective and safe for hair removal.

Для цитирования: Khatri Khalil A, Lee Robert A, Goldberg Lynne J, Khatri Beejul, Garcia Veronica. Efficacy and safety of a 0.65 millisecond pulsed portable ND:YAG laser for hair removal.. Journal of cosmetic and laser therapy : official publication of the European Society for Laser Dermatology. 2009. DOI: 10.1080/14764170802612976.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.