Martius graft for the management of tension-free vaginal tape vaginal erosion.

Al-Wadi Khalid, Al-Badr Ahmed

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The tension-free vaginal tape (TVT) procedure has become standard for the treatment of stress urinary incontinence in women. The procedure carries a risk of vaginal erosion and exposure of the mesh. When this occurs, most surgeons recommend removal of the tape for immediate relief of symptoms. However, this poses a risk of recurrence of urinary incontinence.

CASE: A premenopausal woman had an exposed vaginal mesh after a TVT procedure. After failed conservative treatment, she was treated successfully using a Martius graft, with preservation of the mesh.

CONCLUSION

The Martius procedure was a practical alternative for treating this patient with synthetic-mesh-induced vaginal erosion. It allowed preservation of the sling, thereby preventing recurrence of urinary incontinence.

Для цитирования: Al-Wadi Khalid, Al-Badr Ahmed. Martius graft for the management of tension-free vaginal tape vaginal erosion.. Obstetrics and gynecology. 2009. DOI: 10.1097/aog.0b013e31819eca9b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.