Effects of radiotherapy planning with a dedicated combined PET-CT-simulator of patients with non-small cell lung cancer on dose limiting normal tissues and radiation dose-escalation: a planning study.
Клиническое исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
De Ruysscher Dirk, Wanders Stofferinus, Minken Andre, Lumens Aniek, Schiffelers Jacqueline, Stultiens Cissie, Halders Serve, Boersma Liesbeth, Baardwijk Angela van, Verschueren Tom, Hochstenbag Monique, Snoep Gabriel, Wouters Brad, Nijsten Sebastiaan, Bentzen Søren M, Kroonenburgh Marinus van, Ollers Michel, Lambin Philippe
Аннотация
BACKGROUND AND PURPOSE: To investigate the effect of radiotherapy planning with a dedicated combined PET-CT simulator of patients with locally advanced non-small cell lung cancer.
PATIENTS AND METHODS: Twenty-one patients underwent a pre-treatment simulation on a dedicated hybrid PET-CT-simulator. For each patient, two 3D conformal treatment plans were made: one with a CT based PTV and one with a PET-CT based PTV, both to deliver 60Gy in 30 fractions. The maximum tolerable prescribed radiation dose for CT versus PET-CT PTV was calculated based on constraints for the lung, the oesophagus, and the spinal cord, and the Tumour Control Probability (TCP) was estimated.
RESULTS: For the same toxicity levels of the lung, oesophagus and spinal cord, the dose could be increased from 55.2+/-2.0Gy with CT planning to 68.9+/-3.3Gy with the use of PET-CT (P=0.002), with corresponding TCP's of 6.3+/-1.5% for CT and 24.0+/-5.6% for PET-CT planning (P=0.01).
CONCLUSIONS: The use of a combined dedicated PET-CT-simulator reduced radiation exposure of the oesophagus and the lung, and thus allowed significant radiation dose escalation whilst respecting all relevant normal tissue constraints.
PATIENTS AND METHODS: Twenty-one patients underwent a pre-treatment simulation on a dedicated hybrid PET-CT-simulator. For each patient, two 3D conformal treatment plans were made: one with a CT based PTV and one with a PET-CT based PTV, both to deliver 60Gy in 30 fractions. The maximum tolerable prescribed radiation dose for CT versus PET-CT PTV was calculated based on constraints for the lung, the oesophagus, and the spinal cord, and the Tumour Control Probability (TCP) was estimated.
RESULTS: For the same toxicity levels of the lung, oesophagus and spinal cord, the dose could be increased from 55.2+/-2.0Gy with CT planning to 68.9+/-3.3Gy with the use of PET-CT (P=0.002), with corresponding TCP's of 6.3+/-1.5% for CT and 24.0+/-5.6% for PET-CT planning (P=0.01).
CONCLUSIONS: The use of a combined dedicated PET-CT-simulator reduced radiation exposure of the oesophagus and the lung, and thus allowed significant radiation dose escalation whilst respecting all relevant normal tissue constraints.