Interactive cardiovascular and thoracic surgery · 2017
Three-dimensional virtual bronchoscopy using a tablet computer to guide real-time transbronchial needle aspiration.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fiorelli Alfonso, Raucci Antonio, Cascone Roberto, Reginelli Alfonso, Di Natale Davide, Santoriello Carlo, Capuozzo Antonio, Grassi Roberto, Serra Nicola, Polverino Mario, Santini Mario
Аннотация
OBJECTIVES: We proposed a new virtual bronchoscopy tool to improve the accuracy of traditional transbronchial needle aspiration for mediastinal staging.
METHODS: Chest-computed tomographic images (1 mm thickness) were reconstructed with Osirix software to produce a virtual bronchoscopic simulation. The target adenopathy was identified by measuring its distance from the carina on multiplanar reconstruction images. The static images were uploaded in iMovie Software, which produced a virtual bronchoscopic movie from the images; the movie was then transferred to a tablet computer to provide real-time guidance during a biopsy. To test the validity of our tool, we divided all consecutive patients undergoing transbronchial needle aspiration retrospectively in two groups based on whether the biopsy was guided by virtual bronchoscopy (virtual bronchoscopy group) or not (traditional group). The intergroup diagnostic yields were statistically compared.
RESULTS: Our analysis included 53 patients in the traditional and 53 in the virtual bronchoscopy group. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the traditional group were 66.6%, 100%, 100%, 10.53% and 67.92%, respectively, and for the virtual bronchoscopy group were 84.31%, 100%, 100%, 20% and 84.91%, respectively. The sensitivity ( P = 0.011) and diagnostic accuracy ( P = 0.011) of sampling the paratracheal station were better for the virtual bronchoscopy group than for the traditional group; no significant differences were found for the subcarinal lymph node.
CONCLUSIONS: Our tool is simple, economic and available in all centres. It guided in real time the needle insertion, thereby improving the accuracy of traditional transbronchial needle aspiration, especially when target lesions are located in a difficult site like the paratracheal station.
METHODS: Chest-computed tomographic images (1 mm thickness) were reconstructed with Osirix software to produce a virtual bronchoscopic simulation. The target adenopathy was identified by measuring its distance from the carina on multiplanar reconstruction images. The static images were uploaded in iMovie Software, which produced a virtual bronchoscopic movie from the images; the movie was then transferred to a tablet computer to provide real-time guidance during a biopsy. To test the validity of our tool, we divided all consecutive patients undergoing transbronchial needle aspiration retrospectively in two groups based on whether the biopsy was guided by virtual bronchoscopy (virtual bronchoscopy group) or not (traditional group). The intergroup diagnostic yields were statistically compared.
RESULTS: Our analysis included 53 patients in the traditional and 53 in the virtual bronchoscopy group. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the traditional group were 66.6%, 100%, 100%, 10.53% and 67.92%, respectively, and for the virtual bronchoscopy group were 84.31%, 100%, 100%, 20% and 84.91%, respectively. The sensitivity ( P = 0.011) and diagnostic accuracy ( P = 0.011) of sampling the paratracheal station were better for the virtual bronchoscopy group than for the traditional group; no significant differences were found for the subcarinal lymph node.
CONCLUSIONS: Our tool is simple, economic and available in all centres. It guided in real time the needle insertion, thereby improving the accuracy of traditional transbronchial needle aspiration, especially when target lesions are located in a difficult site like the paratracheal station.