MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11547-013-0326-3

Медицинская библиотека · La Radiologia medica · 2013

Head and neck intensity modulated radiotherapy parotid glands: time of re-planning.

Fiorentino Alba, Cozzolino Mariella, Caivano Rocchina, Pedicini Piernicola, Oliviero Caterina, Chiumento Costanza, Clemente Stefania, Fusco Vincenzo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the correct time point for re-planning by evaluating dosimetric changes in the parotid glands (PGs) during intensity-modulated radiotherapy (IMRT) in head and neck cancer patients.

MATERIALS AND

METHODS

Patients with head and neck cancer treated with IMRT were enrolled. During treatment all patients underwent cone-beam computed tomography (CBCT) scans to verify the set-up. CBCT scans at treatment days 10, 15, 20 and 25 were used to transfer the original plan (CBCTplan I, II, III, IV, respectively) using rigid registration between the two. The PGs were retrospectively contoured and evaluated with the dose-volume histogram. The mean dose, the dose to 50 % of volume, and the percentage of volume receiving 30 and 50 Gy were evaluated for each PG. The Wilcoxon sign ranked test was used to evaluate the effects of dosimetric variations and values <0.05 were taken to be significant.

RESULTS

From February to June 2011, ten patients were enrolled and five IMRT plans were evaluated for each patient. All the dosimetric parameters increased throughout the treatment course. However, this increase was statistically significant at treatment days 10 and 15 (CBCTplan I, II; p = 0.02, p = 0.03, respectively).

CONCLUSION

CBCT is a feasible method to assess the dosimetric changes in the PGs. Our data showed that checking the PG volume and dose could be indicated during the third week of treatment.

Для цитирования: Fiorentino Alba, Cozzolino Mariella, Caivano Rocchina, Pedicini Piernicola, Oliviero Caterina, Chiumento Costanza, Clemente Stefania, Fusco Vincenzo. Head and neck intensity modulated radiotherapy parotid glands: time of re-planning.. La Radiologia medica. 2013. DOI: 10.1007/s11547-013-0326-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.