m+Medelevator.RU
← Поиск публикаций
Minerva urologica e nefrologica = The Italian journal of urology and nephrology · 2018

Intraoperative assessment of ureteral and graft reperfusion during robotic kidney transplantation with indocyanine green fluorescence videography.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vignolini Graziano, Sessa Francesco, Greco Isabella, Cito Gianmartin, Vanacore Davide, Cocci Andrea, Sessa Maurizio, Grandi Vieri, Pili Alessandro, Giancane Saverio, Gacci Mauro, Sebastianelli Arcangelo, Li Marzi Vincenzo, Breda Alberto, Campi Riccardo, Serni Sergio

Аннотация

BACKGROUND: The aim of this paper is to report the first preliminary experience with intraoperative indocyanine green (ICG) fluorescence videography (IFV) to assess graft and ureteral reperfusion during robot-assisted kidney transplantation (RAKT).

METHODS: We prospectively collected data from consecutive patients undergoing RAKT and IFV from living-donors at our Institution between January 2017 and April 2018. RAKT was performed following the principles of the Vattikuti-Medanta technique. ICG was injected intravenously after vascular anastomoses to quantitate graft and ureteral fluorescence signal. The signal intensity within selected intraoperative snapshots was evaluated for renal parenchyma, ureter and vascular anastomoses. A systematic review of the English-language literature about the topic was performed according to the PRISMA statement recommendations.

RESULTS: Six patients were included. Neither conversions to open surgery nor major intra- or postoperative complications were recorded. At a median follow-up of 12 months (IQR 8-13), median estimated glomerular filtration rate was 64.2 mL/min/1.73 m2 (IQR 45.3-98.4). Intraoperative quantitative assessment of ICG fluorescence was successful in all patients. Of the five studies selected by our review, mostly prospective studies, all including open KT series. Yet, most studies were limited by lack of quantitative measures of IFV fluorescence.

CONCLUSIONS: IFV during RAKT is feasible and safe and provides a reliable assessment of graft reperfusion. Larger studies are needed to standardize the technique and to evaluate the association between fluorescence signal, ultrasound parameters and postoperative kidney function.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты