MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-016-0196-2

Медицинская библиотека · BMC ophthalmology · 2016

Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

Spierer Oriel, Waisbourd Michael, Golan Yitzhak, Newman Hadas, Rachmiel Rony

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To protect from erosion of the tube in glaucoma drainage device (GDD), the tube is covered by a biologic tissue which is roofed by the conjunctiva. Sclera, pericardium, dura mater and cornea are available as a patch graft. Drawbacks of some of these materials may include high cost and poor appearance. The purpose of this study is to report the long-term outcomes of partial thickness corneal grafts to cover the tube and prevent its exposure, in GDD surgeries.

METHODS

This was a retrospective review of all patients who underwent Ahmed glaucoma valve implantation and had a minimum follow-up of 12 months. The tube was covered by a 300-micron partial thickness corneal graft taken either from a previous Descemet stripping endothelial keratoplasty procedure or cut from a whole corneal graft button unsuitable for keratoplasty.

RESULTS

Forty-four patients (45 eyes, mean follow-up of 27.6 ± 11.4 months) were enrolled. The partial thickness corneal grafts maintained clarity throughout follow-up with satisfactory cosmetic results. Mild conjunctival retraction occurred in 4 eyes (8.9%) between 1 and 12 months after the surgery. Corneal graft melting occurred in 3 (6.7%) eyes. Tube exposure and additional surgery to re-patch or suture the conjunctiva over the tube was needed in 1 (2.2%) eye. None of the patients had graft infection or immunologic rejection.

CONCLUSIONS

Partial thickness corneal grafts have favorable long-term outcome as a patch for GDD tubes with low rates of tube exposure and other complications.

Для цитирования: Spierer Oriel, Waisbourd Michael, Golan Yitzhak, Newman Hadas, Rachmiel Rony. Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.. BMC ophthalmology. 2016. DOI: 10.1186/s12886-016-0196-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.