m+Medelevator.RU
← Поиск публикаций
Photodiagnosis and photodynamic therapy · 2024

Evaluation of corneal densitometry values with Pentacam in cases of ocular hypertension and pseudoexfoliative glaucoma.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Coskun Cigdem, Çelik Gökhan, Zeki Fikret Cenk, Çomçalı Sebile, Evren Kemer Özlem

Аннотация

BACKGROUND: Examination of corneal densitometry measurements using the Pentacam Scheimpflug imaging system in cases of pseudoexfoliative glaucoma (PEXG) and ocular hypertension (OHT).

METHODS: The study included 50 eyes of 29 PEXG patients, 25 eyes of 16 OHT patients, and 76 eyes of 38 healthy control subjects followed in the glaucoma clinic. Corneal densitometry values of all cases were measured using the Scheimpflug imaging system (Pentacam, Oculus, Germany). Corneal densitometry was assessed based on 4 concentric radial zones (0-2 mm, 2-6 mm, 6-10 mm, and 10-12 mm) and depths (anterior, central, posterior, and total) within the Scheimpflug imaging system. The results were statistically analyzed.

RESULTS: Corneal densitometry values examined between the OHT and control groups were higher in OHT and statistically significant (p < 0.05). Corneal densitometry values examined between the PEXG and control groups were higher in PEXG and statistically significant (p < 0.05). In comparison between the PEXG and OHT groups, corneal densitometry values in the central 0-2 mm, 2-6 mm, and 6-10 mm; posterior 0-2 mm and 2-6 mm radial zones were higher in PEXG and statistically significant (p < 0.05).

CONCLUSIONS: It was observed that elevated intraocular pressure levels in OHT cases could lead to changes in the cornea, consequently increasing corneal densitometry values. The higher corneal densitometry values in PEXG cases compared to OHT were attributed to the accumulation of pseudoexfoliative material in the cornea. Based on our study, corneal densitometry could serve as a potential biomarker for early glaucoma detection in OHT cases and could be employed to assess corneal transparency during the follow-up of PEXG cases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты