MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-21815-8

Медицинская библиотека · Scientific reports · 2025

Test-retest reliability of intra-epidermal electrically evoked potentials in comparison with other modalities and across stimulation intensities.

Júlio Sara U, Rüegge Pascale, Schneuwly Miriam, Hong Kevin, Hubli Michèle, Schubert Martin

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

Intra-epidermal electrically evoked potentials (IEEPs) might represent a promising method for an improved characterization of certain spinal pathologies. Before successful clinical implementation, investigating IEEPs reliability is a prerequisite. This study aimed to assess the test-retest reliability of IEEPs compared to contact heat (CHEPs) and pinprick (PEPs) evoked potentials (Experiment 1) and across different intra-epidermal electrical stimulation (IES) intensities (Experiment 2). Experiment 1 included 26 participants (12f, 25.3 ± 4.6years) and assessed pain-related evoked potentials (PREPs) following contact heat (35-60 °C), pinprick (256 mN), and IES (2 × electrical detection threshold, EDT) to the volar forearm. Experiment 2 included 30 participants (20f, 27.7 ± 3.7years) and assessed IEEPs at four IES intensities (1.5 ×, 2 ×, 4 × EDT, and 0.5 mA). Both experiments assessed test-retest reliability with intraclass correlation coefficients (ICCs) and Bland-Altman analyses for N-latencies, NP-amplitudes, and pain ratings. While IEEPs at 2 × EDT in Experiment 1 showed "excellent" reliability for NP-amplitude, comparable to CHEPs and PEPs, reliability for N-latency and pain ratings ranged from "poor" to "fair". This reliability of IEEP N-latencies and pain ratings improved to "good" and "excellent" by applying higher intensities of IES such as 4 × EDT and 0.5 mA. Given the high reliability of IEEPs at 4 × EDT and 0.5 mA, these intensities may be recommendable for clinical application.

Для цитирования: Júlio Sara U, Rüegge Pascale, Schneuwly Miriam, Hong Kevin, Hubli Michèle, Schubert Martin. Test-retest reliability of intra-epidermal electrically evoked potentials in comparison with other modalities and across stimulation intensities.. Scientific reports. 2025. DOI: 10.1038/s41598-025-21815-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.