MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jcp-2025-210078

Медицинская библиотека · Journal of clinical pathology · 2026

Intraoperative evaluation of sentinel lymph nodes in patients with breast cancer treated with systemic neoadjuvant therapy: a systematic review and meta-analysis of diagnostic studies.

Huerta-Rosario Mariela, Quispe-Vicuña Carlos, Julca-Marín Dante, Zumaran-Nuñez Carlos J, Baltazar-Ñahui Hans, Acuña-Chávez Luis M, Medina-Navia Fiorella, Nieto-Gutierrez Wendy, Alva-Diaz Carlos, Sahoo Sunati

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

BACKGROUND

Frozen section (FS) and touch imprint (TI) are common intraoperative evaluation (IOE) techniques for sentinel lymph nodes (SLNs) in breast cancer surgery. Their accuracy in patients receiving neoadjuvant systemic therapy (NST) remains variable.

OBJECTIVE

To summarise evidence on the diagnostic accuracy of FS and TI in the NST context.

METHODS

A systematic search of PubMed, Embase, Scopus and Web of Science was conducted through April 2024 for studies evaluating FS and/or TI in SLNs of breast cancer patients treated with NST. Meta-analysis was performed using the logit function, and Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies-2 and Grading of Recommendation, Assessment, Development and Evaluation were employed to assess risk of bias and evidence certainty.

RESULTS

20 studies were included. At the lymph node level, TI demonstrated pooled sensitivity and specificity of 0.54 and 1.00, respectively, while FS achieved 0.85 and 0.99. At the patient level, TI showed sensitivity and specificity of 0.72 and 1.00, while FS reached 0.82 and 0.98. Combined, FS and TI presented pooled sensitivity and specificity of 0.59 and 1.00 at the patient level. Risk of bias was frequently unclear, and the certainty of evidence for both techniques ranged from low to very low.

CONCLUSION

FS exhibits higher sensitivity and specificity than TI at both lymph node and patient levels, but evidence certainty remains limited. Further prospective, blinded studies are needed to validate these findings and optimise IOE methods for NST-treated patients.

PROSPERO REGISTRATION NUMBER: CRD42023483079.

Для цитирования: Huerta-Rosario Mariela, Quispe-Vicuña Carlos, Julca-Marín Dante, Zumaran-Nuñez Carlos J, Baltazar-Ñahui Hans, Acuña-Chávez Luis M, Medina-Navia Fiorella, Nieto-Gutierrez Wendy, Alva-Diaz Carlos, Sahoo Sunati. Intraoperative evaluation of sentinel lymph nodes in patients with breast cancer treated with systemic neoadjuvant therapy: a systematic review and meta-analysis of diagnostic studies.. Journal of clinical pathology. 2026. DOI: 10.1136/jcp-2025-210078.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.