MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urology.2018.08.013

Медицинская библиотека · Urology · 2018

Predictive Validation of a Robotic Virtual Reality Simulator: The Tube 3 module for Practicing Vesicourethral Anastomosis in Robot-Assisted Radical Prostatectomy.

Shim Ji Sung, Noh Tae Il, Kim Jae Yoon, Pyun Jong Hyun, Cho Seok, Oh Mi Mi, Kang Seok Ho, Cheon Jun, Lee Jeong Gu, Kim Je Jong, Kang Sung Gu

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To predict actual performance in real surgery when vesicourethral anastomosis (VUA) is performed in patients after Tube 3 module training of robot-naive surgeons.

METHODS

Forty-five patients were enrolled and divided into 3 groups according to chronological trends (each containing 15 patients). Three robot-naive surgeons in a single center completed VUA in robot-assisted radical prostatectomy (RARP) following robotic virtual reality simulator (RVRS) training. The practicing tool used in robotic virtual reality simulator was Tube 3, which was invented for the dV-Trainer that imitates a VUA in RARP. The effects of performance were investigated by analyzing the number of repetitions and the time required to complete the task until achieving the predetermined proficiency level.

RESULTS

The targeted time (predetermined proficiency level) for completing tasks of Tube 3 and the number of required task repetitions to achieve the proficiency level were 283.1 s and 36 times, respectively, whereas in actual VUA procedures, the number of required attempts was 24, with an average time of 14.9 minutes. The mean time for completing VUA in real surgery significantly decreased with serial cases among all surgeons (1-15 vs 16-30 vs 31-45 cases, P <.001), as well as comparisons between groups (P <.001).

CONCLUSION

The Tube 3 module can represent a valuable educational tool for procedure-specific robotic training by bridging the gap between safe acquisition of surgical skills and effective performance during actual VUA in RARP.

Для цитирования: Shim Ji Sung, Noh Tae Il, Kim Jae Yoon, Pyun Jong Hyun, Cho Seok, Oh Mi Mi, Kang Seok Ho, Cheon Jun, Lee Jeong Gu, Kim Je Jong, Kang Sung Gu. Predictive Validation of a Robotic Virtual Reality Simulator: The Tube 3 module for Practicing Vesicourethral Anastomosis in Robot-Assisted Radical Prostatectomy.. Urology. 2018. DOI: 10.1016/j.urology.2018.08.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.