Ultrasound Biomicroscopy of shallow anterior chamber in Vogt-Koyanagi-Harada syndrome.

Gohdo T, Tsukahara S

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We studied a case of Vogt-Koyanagi-Harada syndrome in a patient with a shallow anterior chamber.

METHODS

High-resolution, anterior segment ultrasound biomicroscopy was performed to analyze the mechanism of a shallow anterior chamber.

RESULTS

Ultrasound biomicroscopy disclosed a slit-like narrow angle and circumferential supraciliary fluid. The ciliary body was rotated anteriorly, and the iris showed anterior bowing consistent with pupillary block. With systemic corticosteroid treatment, the supraciliary fluid disappeared, and the ciliary body reverted to its normal position.

CONCLUSION

Ultrasound biomicroscopy was useful in diagnosis and evaluation of the response to corticosteroid treatment in a patient with Vogt-Koyanagi-Harada syndrome accompanied by shallow anterior chamber.

Для цитирования: Gohdo T, Tsukahara S. Ultrasound Biomicroscopy of shallow anterior chamber in Vogt-Koyanagi-Harada syndrome.. American journal of ophthalmology. 1996. DOI: 10.1016/s0002-9394(14)71973-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.