MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Journal of glaucoma · 1996

Contact and noncontact transscleral neodymium:YAG laser cyclophotocoagulation in a rabbit model.

Choi T B, Noriega J F, Glasgow B J, Lee D A

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Contact versus noncontact transscleral neodymium:YAG laser cyclophotocoagulation was compared in a rabbit model with respect to the effects on intraocular pressure and pathologic findings.

METHODS

Thirty-two rabbits received comparable energy levels (2 joules) of contact and noncontact cyclophotocoagulation. Pneumotonometry was performed every other day following treatment.

RESULTS

For both the 2-week and 8-week periods following treatment, intraocular pressure was significantly lower in eyes receiving contact cyclophotocoagulation than in eyes receiving noncontact cyclophotocoagulation (for the 2-week period, mean difference in intraocular pressure was 5.3 mm Hg, n = 22, p < 0.001; for the 8-week period, mean difference in intraocular pressure was 4.3 mm Hg, n = 17, p < 0.013). Pathologic findings include acute ciliary body hemorrhage and inflammation (1 day), chronic inflammation (1 week), granulation tissue within laser lesions (2 weeks), and marked ciliary body atrophy (8 weeks).

CONCLUSIONS

In our rabbit model, contact cyclophotocoagulation was more effective in lowering intraocular pressure than noncontact cyclophotocoagulation. Both contact and noncontact cyclophotocoagulation produced a variety of pathologic lesions in the rabbit eye, including cataract, phthisis bulbi, and anterior synechiae.

Для цитирования: Choi T B, Noriega J F, Glasgow B J, Lee D A. Contact and noncontact transscleral neodymium:YAG laser cyclophotocoagulation in a rabbit model.. Journal of glaucoma. 1996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…