DOI 10.1016/s0161-6420(96)30608-8

Медицинская библиотека · Ophthalmology · 1996

Risk factors for ciliochoroidal effusion after panretinal photocoagulation.

Gentile R C, Stegman Z, Liebmann J M, Dayan A R, Tello C, Walsh J B, Ritch R

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the incidence, duration, and risk factors for ciliochoroidal effusion after panretinal photocoagulation.

METHODS

Thirty-nine consecutive patients with diabetic retinopathy underwent ultrasound biomicroscopy of both eyes to image the ciliochoroidal space immediately before and 1 day after unilateral argon-green panretinal photocoagulation. Imaging was repeated on days 3, 7, and 14 in patients in whom ciliochoroidal effusion developed.

RESULTS

Low-lying ciliochoroidal effusions were imaged in 23 (59%) of 39 eyes. Of 23 eyes, effusions resolved in 6 (26%), 12 (52%), and 5 (22%) eyes by 3, 7, and 14 days respectively. The number of laser applications (P = 0.02), shorter axial length (P = 0.01), and percentage of retinal surface area treated (P = 0.02) were associated with systemic hypertension, location of treatment, previous panretinal photocoagulation of cataract surgery, retinal surface area treated, and mean blood pressure before photocoagulation were not associated with effusion. All fellow, untreated eyes remained effusion-free.

CONCLUSION

Ciliochoroidal effusion develops commonly after panretinal photocoagulation. Limiting the number of laser applications and the percentage of retinal surface area treated reduces the likelihood of this complication. Eyes with shorter axial lengths are at higher risk

Для цитирования: Gentile R C, Stegman Z, Liebmann J M, Dayan A R, Tello C, Walsh J B, Ritch R. Risk factors for ciliochoroidal effusion after panretinal photocoagulation.. Ophthalmology. 1996. DOI: 10.1016/s0161-6420(96)30608-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.