MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00004424-200208000-00002

Медицинская библиотека · Investigative radiology · 2002

Electrical impedance scanning used in addition to ultrasound for the verification of submandibular and parotid lesions: initial results.

Facius M, Malich A, Schneider G, Boehm T, Anderson R, Kaiser W A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Different dielectric properties of cancerous tissues are correlated with increased conductance potentially measurable using Electrical Impedance Scanning (EIS). Sonographically based differentiation of lesions in the salivary glands remains difficult. The clinical value of EIS used additionally to Ultrasound was investigated.

METHODS

Sonographically suspicious lesions of parotid (n = 25) and submandibular (n = 16) glands were examined using TransScan TS2000 (TransScan Medical, Israel; distributed by Siemens, Sweden). Bright focal spots representing areas of high conductance were read as positive; absence of a focal spot (ie, homogeneous gray) was read as negative. All lesions were histopathologically proved.

RESULTS

14/15 malignant (93.3%) and 13/26 benign lesions (50.0%) were correctly detected using EIS, NPV 93%, PPV 52%. All cases of squamous cell carcinoma were correctly identified. Lymph node relapse of T-cell lymphoma, lymph node relapse of malignant melanoma, malignant hemangioendothelioma and 2/3 adenocystic carcinoma (primary metastases) were correctly detected.

CONCLUSIONS

Our initial results suggest EIS to be of interest when used adjunctively to ultrasound for the identification of malignant lesions of the salivary glands. However, low specificity induced in part by current technical restrictions (bone interference, skin alterations, contact artifacts, prominence of the lesions) limit this clinical application.

Для цитирования: Facius M, Malich A, Schneider G, Boehm T, Anderson R, Kaiser W A. Electrical impedance scanning used in addition to ultrasound for the verification of submandibular and parotid lesions: initial results.. Investigative radiology. 2002. DOI: 10.1097/00004424-200208000-00002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.