DOI 10.1007/s00405-019-05280-4
Endoscopic revision stapes surgery: surgical findings and outcomes.
Аннотация
PURPOSE: Hearing results in revision stapes surgery are largely dependent on the cause of failure, and an appropriate intraoperative diagnosis is crucial for a good outcome. The endoscope allows a detailed exploration of the middle ear cavity and is particularly suitable for the intraoperative assessment of the cause of failure of previous stapes surgery. The present study analyzes the intraoperative findings and outcomes of patients undergoing revision stapes surgery through the endoscopic transcanal approach.
METHODS
Surgical videos and charts of patients undergoing endoscopic revision stapes surgery from 2008 to 2017 were reviewed retrospectively. Intraoperative findings, difficulties encountered during the surgery and hearing outcomes were evaluated. The feasibility of each surgical step with the totally endoscopic approach or the need for bimanual manipulation was assessed as well.
RESULTS
Thirty-four patients were included in the study. The endoscopic transcanal approach allowed a detailed exploration of the middle ear cavity and an accurate intraoperative diagnosis and management of the different causes of failure of the previous surgery. 89.8% of patients achieved an air-bone gap for the PTA ≤ 20 dBHL and 68.5% a closure of the air-bone gap.
CONCLUSIONS
The present study showed that totally endoscopic revision stapes surgery is a feasible, safe and effective procedure. The transcanal endoscopic approach allowed an accurate intraoperative diagnosis without the need for an endaural or retroauricular approach, with the possibility to manage all the possible intraoperative scenarios. A larger series with a longer follow-up is needed to validate the results.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.