DOI 10.3760/cma.j.cn112144-20230812-00068
[A follow-up study of the severe occlusal surface wear of implant-supported full-arch prostheses].
Аннотация
Objective
To evaluate the severe occlusal surface wear of implant-supported full-arch prostheses, and to explore the risk factors affecting the severe occlusal surface wear of implant-supported full-arch prostheses.
Methods
Five hundred and thirty-five patients who received implant-supported fixed complete dental prostheses or implant-overdentures and completed at least one follow-up 3 months after the delivery of definitive prostheses were enrolled from October 1994 to October 2021 in this retrospective cohort study. The information on demographics, implants, definitive prostheses, and related outcomes was collected. Cox proportional hazard regression model was adopted to analyze the risk factors of the severe wear of occlusal surfaces in implant-supported full-arch prostheses. Univariate analysis was performed on the factors that may affect the severe wear of occlusal surfaces, and the parameters of P<0.10 in univariate analysis were included in multivariate analysis to explore the risk factors affecting the severe wear of occlusal surfaces in implant-supported full-arch prostheses.
Results
Severe wear of the posterior occlusal surfaces was detected in 114 prostheses with a duration of 61.4 (33.3, 89.4) months. 13 cases occurred ≤2 years after the delivery of definitive prostheses, 44 cases>2 years and ≤5 years, 44 cases>5 years and ≤10 years, and the other 13 cases>10 years. There was no significant difference in the average time of severe occlusal surface wear between implant-supported fixed complete dental prostheses and implant-overdentures in the maxilla (Z=-1.03, P=0.303). However, in the mandible, it was 48.2 (31.2, 80.2) and 79.2 (51.3, 119.1) months respectively, which was statistically significant (Z=-2.93, P=0.003). Cox proportional hazard regression model showed opposed fixed dentition, bruxism, and posterior resin occlusal surfaces were risk factors (P<0.05) affecting the severe wear of the occlusal surfaces.
Conclusions
Severe occlusal surface wear was clinically common with the prolonged application of implant-supported full-arch prostheses. Prostheses opposed to fixed dentition, in patients with bruxism, and made of posterior resin materials were at higher risk of severe occlusal surface wear on the posterior artificial teeth. Regular follow-up, patients' behavior guidance, and clinicians' appropriate intervention were necessary to manage this complication.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.