MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/19433875231163982

Медицинская библиотека · Craniomaxillofacial trauma & reconstruction · 2023

Measuring orbital Volume Using Open Source Software and its Application in Orbitozygomatic Fractures.

Narayan Taradevi P V, Dhupar Vikas

СтатьяПеревод пока не подготовлен

Аннотация

STUDY

DESIGN

Technical note.

OBJECTIVE

Changes in orbital volume can lead to esthetic and functional complications of the orbit. In this article, the procedure to calculate the orbital volume using the open source software Aliza 3D DICOM is described.

METHODS

This article describes the steps to use this novel software. To validate the software, the normal orbital volume was calculated bilaterally on CT scans with normal orbital anatomy. The volumes of unilateral orbitozygomatic fracture cases were compared.

RESULTS

This open source software has easy access. The normal orbital volume calculated using this software was 24.4 cc ± 0.72. In the unilateral orbitozygomatic fracture cases, an increased orbital volume was calculated.

CONCLUSIONS

This easy access, inexpensive, and convenient computer aided software can be used to calculate orbital volume facilitating treatment plan for correction of the orbit volume.

Для цитирования: Narayan Taradevi P V, Dhupar Vikas. Measuring orbital Volume Using Open Source Software and its Application in Orbitozygomatic Fractures.. Craniomaxillofacial trauma & reconstruction. 2023. DOI: 10.1177/19433875231163982.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.