Frontal lobe oxyhemoglobin levels in patients with lower extremity burns assessed using a functional near-Infrared spectroscopy device during usual walking: a pilot study.

Joo So Young, Cho Yoon Soo, Lee Kuem Ju, Lee Seung Yeol, Seo Cheong Hoon

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Understanding the mechanisms associated with locomotor networks may be of benefit for rehabilitation of burn victims with neurological locomotor deficits. A wearable functional near-infrared spectroscopy (fNIRS) device has been developed for studying cortical hemodynamics.

OBJECTIVES

To investigate cortical brain activity during usual walking, we examined patterns of cortical activation using fNIRS device (NIRSIT®; OBELAB Inc., Seoul, Korea), in patients with neurological injury caused by lower extremity burns.

METHODS

This cross-sectional study assessed 15 patients with lower extremity burns, 10 patients with upper extremity burns, and 11 healthy controls. We measured walking-related cortical activity using an fNIRS device at baseline and during usual walking.

RESULTS

There was no significant difference between the burns groups in terms of age (43.50 ± 14.08 and 44.67 ± 6.92 years, P = 1.00), pain score of NRS (Numeric rating scale) (5.83 ± 1.19 and 6.67 ± 1.21, P = 0.18) or the mean time since injury (228.50 ± 83.43 and 199.33 ± 68.84 days, P = 0.78). Measures showed increased cortical activation in the prefrontal cortex in patients with lower extremity burns than in patients with healthy controls(P = 0.015). The measured HbO2 datas of the regions during usual walking in patients with lower extremity burn were insignificantly higher compared with the datas in patient with upper extremity burn (P = 0.302).

CONCLUSIONS

The patients with neurological injury due to lower extremity burns significantly rely more on cognitive resources even when performing a usual walking task.

Для цитирования: Joo So Young, Cho Yoon Soo, Lee Kuem Ju, Lee Seung Yeol, Seo Cheong Hoon. Frontal lobe oxyhemoglobin levels in patients with lower extremity burns assessed using a functional near-Infrared spectroscopy device during usual walking: a pilot study.. Computer methods in biomechanics and biomedical engineering. 2020. DOI: 10.1080/10255842.2020.1812583.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.