Prediction of intracranial lesions in patients with consciousness disturbance by ultrasonography in the intensive care unit.

Shono Yuji, Mezuki Satomi, Akahoshi Tomohiko, Nishihara Masaaki, Kaku Noriyuki, Maki Jun, Tokuda Kentaro, Kitazono Takanari

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study was performed to evaluate the correlation between parameters measured by bedside ultrasonography and detection of intracranial organic lesions in patients with impaired consciousness in an intensive care unit (ICU) setting.

METHODS

We retrospectively reviewed the medical records of patients who were admitted to our ICU from April 2017 to July 2019. Patients who underwent computed tomography or magnetic resonance imaging examination and measurement of the flow velocity of the carotid and intracranial arteries and the optic nerve sheath diameter by ultrasonography were selected for analysis.

RESULTS

In total, 64 patients were analyzed in this study. Of these, intracranial lesions were detected by computed tomography or magnetic resonance imaging in 17 (27%) patients. The left:right ratio of the end-diastolic velocity of the bilateral common carotid artery (CCA-ED ratio) and the pulsatility index of the middle cerebral artery (MCA-PI) were significantly higher in patients with than in those without intracranial lesions. The cut-off value of the CCA-ED ratio was 1.55 (sensitivity, 66.7%; specificity, 81.6%), and that of the MCA-PI was 1.21 (sensitivity, 57.1%; specificity, 76.7%).

CONCLUSION

Bedside ultrasonography is useful for predicting intracranial lesions requiring therapeutic intervention in ICU patients with impaired consciousness.

Для цитирования: Shono Yuji, Mezuki Satomi, Akahoshi Tomohiko, Nishihara Masaaki, Kaku Noriyuki, Maki Jun, Tokuda Kentaro, Kitazono Takanari. Prediction of intracranial lesions in patients with consciousness disturbance by ultrasonography in the intensive care unit.. The Journal of international medical research. 2022. DOI: 10.1177/03000605221119358.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.