MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/01676830.2022.2114502

Медицинская библиотека · Orbit (Amsterdam, Netherlands) · 2022

A technique for excisional optic nerve biopsy.

Ing Edsel B, Nassrallah Georges, Njihawan Navdeep, Micieli Jonathan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe a transconjunctival technique for full-thickness (excisional) optic nerve biopsy.

METHOD: A medial transconjunctival approach to the optic nerve with disinsertion of the medial rectus is used. A small right-angle Mixter forcep is used to clamp the optic nerve far posteriorly, and then a microscalpel is directed metal-on-metal to cut the posterior optic nerve. The cut nerve is then rotated anteriorly to complete the proximal nerve cut.

RESULT: A full-thickness specimen of 11 mm of more can be obtained without undue traction on the globe. The globe remains viable.

CONCLUSION

A long length, excisional optic nerve biopsy can be readily and safely performed without endoscopic techniques.