MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2463/mrms.mp.2024-0046

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2024

Diffusion-weighted Echo Planar Imaging with Compressed SENSE (EPICS-DWI) for Pancreas Assessment: A Multicenter Study.

Kaga Tetsuro, Noda Yoshifumi, Asano Masashi, Kawai Nobuyuki, Kajita Kimihiro, Takai Yukiko, Ejima Fumitaka, Hyodo Fuminori, Kato Hiroki, Fukukura Yoshihiko, Matsuo Masayuki

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to evaluate the feasibility of single-shot echo planar diffusion-weighted imaging with compressed SENSE (EPICS-DWI) for pancreas assessment by comparing with single-shot echo planar DWI with parallel imaging (PI-DWI).

METHODS

This multicenter prospective study included 27 consecutive participants with untreated pancreatic ductal adenocarcinoma (PDAC) (15 men; mean age, 67 ± 10 years) who underwent pancreatic protocol MRI including both PI-DWI and EPICS-DWI. Two radiologists independently and randomly reviewed the high b-value DWI images and qualitatively assigned confidence scores for overall image quality, image noise, pancreas conspicuity, and PDAC conspicuity using a 5-point scale. One radiologist measured the PDAC-to-pancreas contrast-to-noise-ratio (CNR) on high b-value DWI images and the apparent diffusion coefficient (ADC) value of PDAC. Qualitative and quantitative parameters were compared between PI-DWI and EPICS-DWI using the Wilcoxon signed-rank test.

RESULTS

The confidence scores for overall image quality (P < 0.001 in both radiologists) and image noise (P < 0.001 in both radiologists) were higher in EPICS-DWI than in PI-DWI. The pancreas conspicuity was better in EPICS-DWI than in PI-DWI in one of the radiologists (P = 0.02 and 0.06). The PDAC conspicuity was comparable between PI-DWI and EPICS-DWI (P > 0.99 in both radiologists). The PDAC-to-pancreas CNR was higher in EPICS-DWI than in PI-DWI (P = 0.02), while the ADC value of PDAC in PI-DWI was not significantly different compared to that in EPICS-DWI (P = 0.48).

CONCLUSION

The image quality and PDAC-to-pancreas CNR was improved in EPICS-DWI compared to PI-DWI. However, the conspicuity and ADC value of PDAC were comparable between PI-DWI and EPICS-DWI.

Для цитирования: Kaga Tetsuro, Noda Yoshifumi, Asano Masashi, Kawai Nobuyuki, Kajita Kimihiro, Takai Yukiko, Ejima Fumitaka, Hyodo Fuminori, Kato Hiroki, Fukukura Yoshihiko, Matsuo Masayuki. Diffusion-weighted Echo Planar Imaging with Compressed SENSE (EPICS-DWI) for Pancreas Assessment: A Multicenter Study.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2024. DOI: 10.2463/mrms.mp.2024-0046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.