Acta oncologica (Stockholm, Sweden) · 1993
Radioimmunoimaging of non-small cell lung cancer with 111In- and 99mTc-labeled monoclonal anti-CEA-antibodies.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kairemo K J, Aronen H J, Liewendahl K, Paavonen T, Heikkonen J J, Virkkunen P, Mäki-Hokkonen H, Karonen S L, Brownell A L, Mäntylä M J
Аннотация
Radiolabeled monoclonal anti-CEA antibodies were used for radioimmunolocalization (RIL) of non-small cell lung cancer; in 30 patients with 111In labeled anti CEA F(ab')2 fragment (BW 431/31) and in 16 with 99mTc-labeled intact MoAb (BW 431/26). RIL results were compared with those of other imaging modalities. Paraffin sections from some patients were also studied immunohistochemically using anti-CEA antibody. Patients with 111In labeled MoAB were imaged twice 1-4 days after injection and for image enhancement pulmonary and liver/spleen subtraction were performed. Twenty-seven of 28 primary tumors were positive and metastases were detected in all patients. The total number of lesions was 78 of which 61 (78%) could be detected by RIL. For verification CT was applied to the study of 46 lesions detected by RIL. We found 6 unknown lesions subsequently verified histologically. Using subtraction techniques we detected 9 lesions in 4 patients, later verified as pulmonary metastases, not detected in unprocessed images. Pleural, mediastinal and pericardial lesions were also better delineated in subtracted images than in unprocessed images. Imaging of non-small cell lung cancer with 99mTc-labeled MoAB was performed twice 4-24 h after injection. RIL results were compared with other imaging methods; CT US, conventional radiography, and immunohistochemistry. Twelve out of 16 patients with suspected or known lung cancer had positive immunoscintigrams; 19 of 25 lesions could be detected by RIL. There were 5 false positive and 2 true negative findings. Immunoperoxidase (IP) stainings of paraffin sections of the tumours from 7 patients were performed using two different anti-CEA antibodies; BW 431/26 and ZCEA1. None of the seven tumors examined by immunohistochemistry were negative when stained by BW 431/26, which was the antibody used for immunoscintigraphy.