DOI 10.1016/j.jtho.2024.05.006
A Real-World Assessment of Stage I Lung Cancer Through Electronic Nose Technology.
Аннотация
INTRODUCTION
Electronic nose (E-nose) technology has reported excellent sensitivity and specificity in the setting of lung cancer screening. However, the performance of E-nose specifically for early-stage tumors remains unclear. Therefore, the aim of our study was to assess the diagnostic performance of E-nose technology in clinical stage I lung cancer.
METHODS
This phase IIc trial (NCT04734145) included patients diagnosed with a single greater than or equal to 50% solid stage I nodule. Exhalates were prospectively collected from January 2020 to August 2023. Blinded bioengineers analyzed the exhalates, using E-nose technology to determine the probability of malignancy. Patients were stratified into three risk groups (low-risk, [<0.2]; moderate-risk, [≥0.2-0.7]; high-risk, [≥0.7]). The primary outcome was the diagnostic performance of E-nose versus histopathology (accuracy and F1 score). The secondary outcome was the clinical performance of the E-nose versus clinicoradiological prediction models.
RESULTS
Based on the predefined cutoff (<0.20), E-nose agreed with histopathologic results in 86% of cases, achieving an F1 score of 92.5%, based on 86 true positives, two false negatives, and 12 false positives (n = 100). E-nose would refer fewer patients with malignant nodules to observation (low-risk: 2 versus 9 and 11, respectively; p = 0.028 and p = 0.011) than would the Swensen and Brock models and more patients with malignant nodules to treatment without biopsy (high-risk: 27 versus 19 and 6, respectively; p = 0.057 and p < 0.001).
CONCLUSIONS
In the setting of clinical stage I lung cancer, E-nose agrees well with histopathology. Accordingly, E-nose technology can be used in addition to imaging or as part of a "multiomics" platform.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.