MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ygyno.2014.08.032

Медицинская библиотека · Gynecologic oncology · 2014

Accuracy of robotic sentinel lymph node detection (RSLND) for patients with endometrial cancer (EC).

Desai Pranjal H, Hughes Patrick, Tobias Daniel H, Tchabo Nana, Heller Paul B, Dise Craig, Slomovitz Brian M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Lymphadenectomy as a part of the staging for EC patients is controversial. Sentinel lymph node detection has been introduced to determine which patients would benefit from adjuvant therapy and to limit morbidities associated with a full pelvic nodal dissection. The purpose of this study is to evaluate diagnostic accuracy and detection rate of robotic sentinel lymph node detection (RSLND) as a part of the surgical staging for EC.

METHODS

A retrospective database of all patients who underwent intraoperative lymphatic mapping using cervical injection methylene blue followed by RSLND as a part of their procedure was reviewed. Sentinel lymph node (SLN) was initially examined by routine Hematoxylin and Eosin (H&E) and ultrastaging by immunohistochemistry (IHC).

RESULTS

Between 4/2011 and 6/2013, 120 patients with endometrial cancer underwent RSLND. The median age was 62years (25-87); median BMI was 32 (18-76). Out of 120 patients, only one patient underwent RSLND with fertility preservation; and 119 patients underwent robotic hysterectomy and surgical staging with RSLND. None of the cases was converted to an open procedure. At least 1 SLN was detected in 86% (103/120) of the patients. Bilateral SLNs were detected in 52% (62/120). Positive nodes were identified in 8% (10/120) of the patients. Of those with SLN (+), 50% (5/10) were by ultrastaging (IHC) alone. No patients had positive regional nodes without SLN (+).

CONCLUSIONS

RSLND using methylene blue cervical injection can identify SLN in most patients with EC. IHC ultrastaging improves the detection of node positive disease when compared to traditional pathological evaluation.

Для цитирования: Desai Pranjal H, Hughes Patrick, Tobias Daniel H, Tchabo Nana, Heller Paul B, Dise Craig, Slomovitz Brian M. Accuracy of robotic sentinel lymph node detection (RSLND) for patients with endometrial cancer (EC).. Gynecologic oncology. 2014. DOI: 10.1016/j.ygyno.2014.08.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.