m+Medelevator.RU
← Поиск публикаций
Scandinavian journal of gastroenterology. Supplement · 2004

FDG-PET scanning in the diagnosis of gastrointestinal cancers.

СтатьяПоддержка исследования: вне правительства СШАОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

van Kouwen M C A, Oyen W J G, Nagengast F M, Jansen J B M J, Drenth J P H

Аннотация

This review deals with the current, well-established indications for two-(18F)-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) scanning in patients with gastrointestinal cancers. FDG-PET is a non-invasive, functional imaging technique. FDG exploits the native glucose transporter to enter the cell. Since many tumours have enhanced glucose uptake, FDG is readily accumulated in malignant cells and can be detected by a PET camera. FDG-PET has been established as an important diagnostic tool in clinical oncology. This review deals with the current, well-established indications for FDG-PET scanning in patients with gastrointestinal cancers. In the current practice, FDG-PET is most commonly used to stage oesophageal carcinoma, to detect and stage recurrence of colorectal carcinoma and to differentiate between benign and malignant pancreatic lesions. The benefit of FDG-PET scanning in patients with oesophagus carcinoma is best established in stage IV disease, as the diagnostic accuracy to detect metastatic disease is higher compared to the combination of computed tomography (CT) and endoscopic ultrasound (EUS). In patients with a history of colorectal carcinoma, FDG-PET scanning is particularly effective in diagnosing recurrent disease, especially in those with a rising carcinoembryonic antigen without a suspect lesion on conventional imaging. Large series have indicated that the sensitivity and specificity for detecting recurrent colorectal carcinoma are in the range of 87%-100% and 66%-100%, respectively. Equally, FDG-PET has a high sensitivity (68%-96%) and specificity (78%-100%) in detecting pancreatic carcinoma in patients with a suspicious-looking pancreatic mass on CT scan. Lastly, we focus on the use of FDG-PET as a modality for early monitoring of treatment response in patients with gastrointestinal stromal cell tumours. Without doubt, future developments will further establish the diagnostic role of the FDG-PET scan in the care of patients with gastrointestinal cancers.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты