MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1574-6968.2009.01779.x

Медицинская библиотека · FEMS microbiology letters · 2009

Loop-mediated isothermal amplification targeting the apxIVA gene for detection of Actinobacillus pleuropneumoniae.

Yang Wang, Pin Chen, Haibing Guo, Yang Chen, Hui Liu, Qigai He

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method performed under isothermal conditions with high specificity and efficiency. We developed a diagnostic method based on LAMP for detection of Actinobacillus pleuropneumoniae. Using six specific primers targeting the apxIVA gene, the LAMP assay rapidly amplified the target gene within 30 min, requiring only a laboratory water bath for the reaction to occur. The resulting amplificon was visualized by adding SYBR Green I to the mixture. The results obtained from testing 15 A. pleuropneumoniae reference strains and other seven bacterial species strains showed that the LAMP was as specific as and 10 times more sensitive than nested PCR. Sixty-five tonsil samples were collected from 65 healthy pigs. All the samples were negative for A. pleuropneumoniae by immunomagnetic separation-based (IMS) bacterial isolation, nested PCR and LAMP, respectively. Meanwhile, 115 tonsil samples were also collected from 115 pigs with apparent respiratory problems. Twenty-two were positive by IMS bacterial isolation. All the samples that were positive by IMS bacterial isolation were also positive by nested PCR and LAMP. The LAMP assay demonstrated exceptionally higher sensitivity than nested PCR by picking up 14 additional positive cases (chi(2) test, P<0.0001); we concluded that LAMP was a highly sensitive and reliable method for detection of A. pleuropneumoniae infection.

Для цитирования: Yang Wang, Pin Chen, Haibing Guo, Yang Chen, Hui Liu, Qigai He. Loop-mediated isothermal amplification targeting the apxIVA gene for detection of Actinobacillus pleuropneumoniae.. FEMS microbiology letters. 2009. DOI: 10.1111/j.1574-6968.2009.01779.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.