m+Medelevator.RU
← Поиск публикаций
Journal of the mechanical behavior of biomedical materials · 2018

Characterisation of human urethral rupture thresholds for urinary catheter inflation related injuries.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Davis N F, Cunnane E M, Mooney R O 'c, Hess J, Walsh M T

Аннотация

Data on urethral catheter related injuries is sparse. In this study we aimed to characterise urethral diametric strain and urinary catheter inflation pressure thresholds that precede human urethral trauma during urethral catheterisation (UC). Human urethras were obtained from patients undergoing male to female gender reassignment surgery [(n = 9; age 40 ± 13.13 (range: 18-58)) years]. 12Fr urinary catheters were secured in the bulbar urethra and the catheter's anchoring balloon was inflated with a syringe pump apparatus. Urethral diametric strain and balloon pressure were characterised with video extensometry and a pressure transducer respectively. Immunohistochemistry, Masson's trichrome and Verhoeff-Van Gieson stains evaluated urethral trauma microscopically. Morphological characterisation of the urethral lumen was performed by examining non-traumatised histological sections of urethra and recording luminal area, perimeter and major/minor axis length. Tearing (n = 3) and rupture (n = 3) of the urethra were observed following catheter balloon inflation. The threshold for human urethral rupture occurred at an external urethral diametric strain ≥ 27% and balloon inflation pressure ≥ 120kPa. Significant relationships were identified between urethral wall thickness and the level of trauma induced during catheter balloon inflation (p = 0.001) and between the pressure required to inflate the catheter balloon and the length of the major axis of the urethral lumen (p = 0.004). Ruptured urethras demonstrated complete transection of collagen, elastin and muscle fibres. In conclusion, urethral rupture occurs at an external urethral diametric strain ≥ 27% or with balloon inflation pressures ≥ 120 kPa. Incorporation of these parameters may be useful for designing a safety mechanism for preventing catheter inflation related urethral injuries.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты