MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urology.2007.09.014

Медицинская библиотека · Urology · 2008

Accuracy of ultrasonography in diagnosis of testicular rupture after blunt scrotal trauma.

Guichard Guillaume, El Ammari Jamal, Del Coro Carlos, Cellarier Damien, Loock Pierre Yves, Chabannes Eric, Bernardini Stéphane, Bittard Hugues, Kleinclauss François

Клинический случайСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study is to determine the accuracy of ultrasonography for the diagnosis of testis rupture after scrotal trauma and its sensitivity and specificity for testis rupture, tunica albuginea breach, testicular hematoma, testis avulsion, epididymis injuries, and hematocele.

METHODS

Between 1996 and 2006, 33 patients underwent surgical exploration for blunt scrotal trauma. All these patients had an emergency scrotal ultrasonography with the use of a 7.5 or 10 MHz linear transducer. Ultrasonographic findings were compared with surgical findings to calculate sensitivity and specificity of ultrasonography for each type of lesion.

RESULTS

Of 33 patients, 16 presented a testis rupture. Testis rupture was in all cases suspected ultrasonographically by the loss of contour of the testis and heterogeneous parenchyma. Tunica albuginea breach was visualized in only 8 patients. Sensitivity and specificity of ultrasound for testis rupture were 100% and 65%, respectively. Moreover, ultrasonography allowed diagnosis of hematocele (sensitivity: 87% and specificity: 89%), testicular hematoma (sensitivity: 71%, specificity: 77%), and testis avulsion (sensitivity: 100%, specificity: 97%). Ultrasonography results for epididymis injuries were poor. On 7 patients, 3 epididymis lesions were misdiagnosed by ultrasound examination.

CONCLUSIONS

Ultrasonography can distinguish various scrotal injuries. Testicular rupture is probably the most severe injury that needs early surgical treatment to improve testis salvage rate. In our work, ultrasonography is highly sensitive in the diagnosis of testis rupture and can provide information on the scrotal contents integrity that can help the physician to determine the optimal treatment.

Для цитирования: Guichard Guillaume, El Ammari Jamal, Del Coro Carlos, Cellarier Damien, Loock Pierre Yves, Chabannes Eric, Bernardini Stéphane, Bittard Hugues, Kleinclauss François. Accuracy of ultrasonography in diagnosis of testicular rupture after blunt scrotal trauma.. Urology. 2008. DOI: 10.1016/j.urology.2007.09.014.