MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2017/3805073

Медицинская библиотека · BioMed research international · 2017

Monitoring Leiomyoma Response to Uterine Artery Embolization Using Diffusion and Perfusion Indices from Diffusion-Weighted Imaging.

Cao Mengqiu, Qian Lijun, Zhang Xuebin, Suo Xinjun, Lu Qing, Zhao Huilin, Liu Jialin, Qu Jianxun, Zhou Yan, Xu Jianrong, Suo Shiteng

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the potential of diffusion and perfusion indices (ADC and perfusion fraction f) from DWI at 3.0 T in monitoring treatment response to uterine artery embolization (UAE) at 6-month follow-up.

METHODS

Twelve female patients with uterine fibroids who underwent 3.0-T pelvic DWI before and 6 months after UAE were included. ADC and perfusion fraction f were calculated from DWI. The Wilcoxon signed-rank test and Spearman rank correlation test were used for statistics.

RESULTS

Seventeen fibroids were studied. The median ADCs showed a significant increase from 1.20 × 10-3 mm2/s (range, 0.86-1.66 × 10-3 mm2/s) at baseline to 1.56 × 10-3 mm2/s (range, 1.00-1.86 × 10-3 mm2/s) at 6-month follow-up (P = 0.0003). Conversely, the median perfusion fraction f was significantly decreased after UAE (P = 0.0001), with a median pre-UAE value of 14.2% (range, 6.7%-17.6%) and a median post-UAE value of 9.2% (range, 3.2%-14.6%). Significant correlations were found between fibroid volume reduction rate and percentage changes in ADC and perfusion fraction f at 6-month follow-up relative to baseline, with ρ values of -0.50 (P = 0.04) and 0.55 (P = 0.02), respectively.

CONCLUSION

ADC and perfusion fraction f obtained from DWI at 3.0 T may help to evaluate treatment response to UAE.

Для цитирования: Cao Mengqiu, Qian Lijun, Zhang Xuebin, Suo Xinjun, Lu Qing, Zhao Huilin, Liu Jialin, Qu Jianxun, Zhou Yan, Xu Jianrong, Suo Shiteng. Monitoring Leiomyoma Response to Uterine Artery Embolization Using Diffusion and Perfusion Indices from Diffusion-Weighted Imaging.. BioMed research international. 2017. DOI: 10.1155/2017/3805073.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.