The journal of obstetrics and gynaecology research · 2017
Experimental study on ablation of leiomyoma by combination high-intensity focused ultrasound and iodized oil in vitro.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liang Zhi-Gang, Gao Yi, Ren Xiao-Yan, Sun Cui, Gu Heng-Fang, Mou Meng, Xiao Yan-Bing
Аннотация
AIM: The aim of the current study was to investigate whether iodized oil (IO) enhances high-intensity focused ultrasound (HIFU) ablation of uterine leiomyoma and to determine the features of hyperechoic changes in the target region.
METHODS: Forty samples of uterine leiomyoma were randomly divided into an experimental group and a control group. In the experimental group, the leiomyoma was ablated by HIFU 30 min after 1 mL of iodized oil had been injected into the center of the myoma. The hyperechoic values and areas in the target region were observed by B-modal ultrasound after HIFU ablation. The samples were cut successively into slices and stained by triphenyltetrazolium chloride (TTC) solution within 1 h after HIFU ablation. The diameters of TTC-non-stained areas were measured and tissues in the borderline of the TTC-stained and -non-stained areas were observed pathologically. All procedures in the control group were the same as those in the experimental group except IO was replaced by physiological saline.
RESULTS: The hyperechoic value in the target region in the experimental group was higher than that in the control group 4 min after HIFU ablation (P < 0.05). Hyperechoic areas in the target region as well as TTC-non-stained volumes in the experimental group were greater than those in the control group (P < 0.05). Routine pathologic observation showed that coagulation necrosis of leiomyoma occurred in the target region in both groups.
CONCLUSION: IO causes coagulation necrosis, enlarges tissue damage, and postpones the attenuation of hyperechoic changes in the target region when HIFU ablation is carried out for leiomyoma in vitro.
METHODS: Forty samples of uterine leiomyoma were randomly divided into an experimental group and a control group. In the experimental group, the leiomyoma was ablated by HIFU 30 min after 1 mL of iodized oil had been injected into the center of the myoma. The hyperechoic values and areas in the target region were observed by B-modal ultrasound after HIFU ablation. The samples were cut successively into slices and stained by triphenyltetrazolium chloride (TTC) solution within 1 h after HIFU ablation. The diameters of TTC-non-stained areas were measured and tissues in the borderline of the TTC-stained and -non-stained areas were observed pathologically. All procedures in the control group were the same as those in the experimental group except IO was replaced by physiological saline.
RESULTS: The hyperechoic value in the target region in the experimental group was higher than that in the control group 4 min after HIFU ablation (P < 0.05). Hyperechoic areas in the target region as well as TTC-non-stained volumes in the experimental group were greater than those in the control group (P < 0.05). Routine pathologic observation showed that coagulation necrosis of leiomyoma occurred in the target region in both groups.
CONCLUSION: IO causes coagulation necrosis, enlarges tissue damage, and postpones the attenuation of hyperechoic changes in the target region when HIFU ablation is carried out for leiomyoma in vitro.