MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000000448

Медицинская библиотека · Cornea · 2015

Lid Margin Sensitivity and Staining in Contact Lens Wear Versus No Lens Wear.

Navascues-Cornago Maria, Morgan Philip B, Maldonado-Codina Carole

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To map the sensitivity and staining of the marginal conjunctiva in soft contact lens (SCL) wearers and nonwearers and to investigate diurnal changes.

METHODS

Thirty-five nonwearers and 35 SCL wearers were recruited. Mechanical sensitivity was measured at 8 locations on the ocular surface and adnexa (cornea, marginal, bulbar, and tarsal conjunctivae) using the Cochet-Bonnet aesthesiometer. Lid margin staining (lissamine green) was assessed through image analysis. Measurements were repeated at 12 hours in 11 nonwearers and 10 symptomatic SCL wearers.

RESULTS

The marginal conjunctiva was the most sensitive conjunctival region (all P < 0.001). There was no significant difference in sensitivity at 12 hours (all P > 0.05). There was a significant difference in sensitivity between the 2 groups in the morning for the lower lid tarsal conjunctiva (P = 0.003). After 12 hours, the sensitivity of the lower lid marginal conjunctiva was found to be reduced in SCL wearers compared with nonwearers (all P < 0.05). Lower lid margin staining was greater than upper lid margin staining in both groups (all P < 0.05). In the SCL wearers, a significant increase in lower lid margin staining was found at 12 hours compared with the morning (P = 0.04). After 12 hours, lower lid margin staining was significantly greater in SCL wearers compared with nonwearers (P = 0.03).

CONCLUSIONS

This work has demonstrated that the marginal conjunctiva is the most sensitive conjunctival region. After 12 hours, symptomatic lens wearers showed decreased sensitivity of the lower marginal conjunctiva and increased lower lid margin lissamine green staining compared with those of the nonwearers.

Для цитирования: Navascues-Cornago Maria, Morgan Philip B, Maldonado-Codina Carole. Lid Margin Sensitivity and Staining in Contact Lens Wear Versus No Lens Wear.. Cornea. 2015. DOI: 10.1097/ico.0000000000000448.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.