Effect of Anterior Chamber Air on Central Corneal Thickness in Human Donor Eyes.
Аннотация
PURPOSE: The purpose of this study was to describe the effects of intracameral air on corneal edema.
METHODS
A laboratory investigation was performed on human donor corneas. Baseline pachymetry measurements through anterior segment optical coherence tomography and endothelial cell density were obtained for all corneas. Each pair of corneas was separated and randomly assigned to undergo air injection or Optisol-GS into a BIONIKO artificial anterior chamber for 5 minutes at physiologic intraocular pressure confirmed by digital palpation. Photographs were obtained immediately on connection of the cornea to the artificial anterior chamber and on completion of the 5 minutes of treatment, with anterior chamber air being exchanged for Optisol-GS. Pretreatment and posttreatment photographs were obtained. Immediately after treatment, pachymetry was again obtained on all corneas. Pachymetry data underwent statistical analysis.
RESULTS
Corneal pachymetry improved from 690.5 ± 126.6 to 576.1 ± 87.2 μm, yielding a 114.4 ± 50.4 μm improvement of pachymetry in the group with air injected into the anterior chamber. This was a significant improvement of pachymetry when compared with the group with Optisol-GS injected into the anterior chamber, which showed an improvement from 662.3 ± 126.5 to 613.5 ± 108.0 μm, yielding an improvement of 48.8 ± 34.3 μm.
CONCLUSIONS
Injection of air into the anterior chamber leads to a significant decrease in corneal pachymetry. We thereby propose that injecting air intracamerally is an effective intraoperative intervention when visualization is negatively affected by corneal edema.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.