Eye & contact lens · 2023
Visual Quality Assessment and Comparison of Monofocal and Multifocal Scleral Lens Designs: A Pilot Study.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Privado-Aroco Ana, Valdes-Soria Gonzalo, Romaguera María, Serramito María, Carracedo Gonzalo
Аннотация
PURPOSE: To compare visual quality, contrast sensitivity, stereopsis, subjective vision, and comfort between monofocal and multifocal scleral lens (SL) designs.
METHODS: An experimental, cross over and short-term pilot study has been performed. Nineteen presbyopic patients (51.9±3.8 years) with regular corneas participated voluntarily in the study and Onefit MED monofocal and multifocal SL designs were fitted bilaterally. Subjective vision and comfort, contrast sensitivity function, stereopsis, high- and low-contrast visual acuity (VA) at 4 m and 40 cm under photopic and mesopic conditions, and defocus curves were measured. Data analysis was performed with nonparametric tests. P<0.05 was considered as statistically significant.
RESULTS: Mean addition power of the prescribed lenses was 1.72±0.38 diopters. Multifocal design showed a statistically significant improvement for intermediate and near vision in the defocus curve under photopic and mesopic conditions (P<0.05), however, worsening in stereopsis (P<0.05) and contrast sensitivity for high spatial frequencies (P<0.05). Distance visual acuity (VA) showed significantly lower values under mesopic conditions for high- and low-contrast tests (P<0.05), and on low-contrast test under photopic conditions (P<0.001) with the multifocal design.
CONCLUSION: Multifocal SLs showed better visual performance at intermediate and near distances without compromising distance vision under photopic conditions for a high-contrast test when compared with monofocal design.
METHODS: An experimental, cross over and short-term pilot study has been performed. Nineteen presbyopic patients (51.9±3.8 years) with regular corneas participated voluntarily in the study and Onefit MED monofocal and multifocal SL designs were fitted bilaterally. Subjective vision and comfort, contrast sensitivity function, stereopsis, high- and low-contrast visual acuity (VA) at 4 m and 40 cm under photopic and mesopic conditions, and defocus curves were measured. Data analysis was performed with nonparametric tests. P<0.05 was considered as statistically significant.
RESULTS: Mean addition power of the prescribed lenses was 1.72±0.38 diopters. Multifocal design showed a statistically significant improvement for intermediate and near vision in the defocus curve under photopic and mesopic conditions (P<0.05), however, worsening in stereopsis (P<0.05) and contrast sensitivity for high spatial frequencies (P<0.05). Distance visual acuity (VA) showed significantly lower values under mesopic conditions for high- and low-contrast tests (P<0.05), and on low-contrast test under photopic conditions (P<0.001) with the multifocal design.
CONCLUSION: Multifocal SLs showed better visual performance at intermediate and near distances without compromising distance vision under photopic conditions for a high-contrast test when compared with monofocal design.