Involvement of Eyelid Pressure in Lid-Wiper Epitheliopathy.

Yamamoto Yasuaki, Shiraishi Atsushi, Sakane Yuri, Ohta Kiyohiko, Yamaguchi Masahiko, Ohashi Yuichi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To determine whether eyelid pressure is involved in the development of lid-wiper epitheliopathy (LWE).

METHODS

Study 1: The eyelid pressure was measured with a blepharo-tensiometer, and the degree of LWE was assessed in 79 eyes of 43 non-contact lens (CL) wearers. Study 2: The movements of the eyelids and displacement of the eyes during spontaneous blinking were photographed with a high-speed camera. The eyelid pressure was also measured in 34 normal eyes of 19 non-CL wearers who were not part of Study 1.

RESULTS

Study 1: Upper-LWE was detected in 24 of 79 eyes (30.4%), and no significant difference was detected in the eyelid pressure between any grade of upper-LWE. Lower-LWE was detected in 41 of 79 eyes (51.9%), and the eyelid pressure (27.9 ± 2.8 mmHg) in eyes with grade 3 LWE was significantly higher than that with grade 0 LWE (19.7 ± 1.3 mmHg; p < 0.05). Study 2: The lower eyelid pressure was significantly correlated with the length of the horizontal movement of the lower eyelids (p < 0.05) and also with the degree of posterior movement of the eye globe (p < 0.05).

CONCLUSIONS

The higher pressure from the eyelid may be one of the causes for the development of lower-LWE.

Для цитирования: Yamamoto Yasuaki, Shiraishi Atsushi, Sakane Yuri, Ohta Kiyohiko, Yamaguchi Masahiko, Ohashi Yuichi. Involvement of Eyelid Pressure in Lid-Wiper Epitheliopathy.. Current eye research. 2015. DOI: 10.3109/02713683.2015.1009636.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.