m+Medelevator.RU
← Поиск публикаций
Veterinary ophthalmology · 2015

In vivo evaluation of the cornea and conjunctiva of the normal laboratory beagle using time- and Fourier-domain optical coherence tomography and ultrasound pachymetry.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Strom Ann R, Cortés Dennis E, Rasmussen Carol A, Thomasy Sara M, McIntyre Kim, Lee Shwu-Fei, Kass Philip H, Mannis Mark J, Murphy Christopher J

Аннотация

OBJECTIVE: To obtain normative data for the canine cornea and conjunctiva using high-resolution time- and Fourier-domain optical coherence tomography (TD-OCT and FD-OCT) and ultrasound pachymetry (USP).

ANIMALS: One hundred sixty-eight eyes of 133 healthy young intact laboratory beagles.

PROCEDURES: The cornea and conjunctiva of 16 eyes of 8 healthy young intact female beagles were imaged using FD-OCT. Corneal thickness was measured with FD-OCT and USP, while corneal epithelial thickness and conjunctival epithelial thickness were measured with FD-OCT. The central corneal thickness (CCT) was determined in 152 eyes of 125 healthy young adult intact female (35) and male (90) beagles using TD-OCT. Mixed effects linear regression was used for statistical analysis.

RESULTS: The CCT was (mean ± standard deviation) 497.54 ± 29.76, 555.49 ± 17.19, and 594.81 ± 33.02 μm as measured by FD-OCT, USP, and TD-OCT, respectively. The central, superior paraxial, superior perilimbal corneal epithelial thickness and superior bulbar conjunctival epithelial thickness were 52.38 ± 7.27, 56.96 ± 6.47, 69.06 ± 8.84 and 42.98 ± 6.17 μm, respectively. When comparing techniques used for measuring CCT (USP vs. FD-OCT and FD-OCT vs. TD-OCT), USP and TD-OCT generated significantly greater values in comparison with FD-OCT (both P < 0.001). For all dogs, CCT increased with increasing age and body weight (both P < 0.001) and was higher in intact males vs. females using TD-OCT (P = 0.034).

CONCLUSION: High-resolution FD-OCT and TD-OCT provide detailed noninvasive evaluation of in vivo canine anterior segment structures. Normative values of the canine cornea and conjunctiva are reported.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты