Indian journal of ophthalmology · 2023

The influence of altitude on the differences between Goldmann tonometry and Pascal dynamic contour tonometry: An ecological meta-analysis.

СтатьяМетаанализОбзорСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Albis-Donado Oscar, Ramirez-Neria Paulina, Rios-Acosta Nadia, Stalmans Ingeborg

Аннотация

PURPOSE: A meta-analysis found that including atmospheric pressure as altitude in generalized linear models reveals higher differences between Goldmann tonometry and Pascal dynamic contour tonometry at higher altitudes, with the difference increasing in thinner corneas. To examine the difference in intraocular pressure (IOP) measurements by using Goldman applanation tonometry (GAT) and dynamic contour tonometer (DCT) tonometry in published literature and determine the influence of central corneal thickness (CCT), age, and altitude on that difference.

METHODS: Articles that compare GAT and DCT were selected for an extensive literature review, and the location and altitude of the research centers were found online. CCT and age were analyzed as covariates, when available.

RESULTS: A total of 157 studies including 24,211 eyes of 20,214 patients were included in the study. The results showed that the difference between DCT and GAT was higher at higher altitudes above sea level and increased with thinner corneas. However, the results were different in eyes with corneal transplants, where altitude and CCT had less influence, and in those post-refractive surgery where age was found to influence the difference. Theoretical correction formulas using altitude, CCT, and age were derived from this meta-analysis, but their accuracy and usefulness in clinical practice need validation.

CONCLUSION: The findings suggest that there is a higher risk of underestimating IOP when the Goldmann tonometer is used at a higher altitude, particularly in eyes with glaucoma, thinner corneas, or corneal refractive surgery. Further research is needed to validate the accuracy of the correction formulas derived from this meta-analysis in clinical practice.