Analysis of orbitofacial anthropometry in children with pseudostrabismus.

Kavitha V, Mooss Vidya S, Ravishankar H N, Heralgi Mallikarjun M, Puliappadamb Haridas Mundot

СтатьяПеревод пока не подготовлен

Аннотация

AIM: The aim of the study was to analyze orbitofacial anthropometric parameters such as inner and outer canthal distances (ICD and OCD), palpebral fissure length (PFL), interpupillary distance (IPD), and canthal index (CI) in children with pseudostrabismus and to compare the measured IPD (mIPD) with calculated IPD (cIPD).

MATERIALS AND

METHODS

This was a prospective study of sixty children (6 months-18 years) with pseudostrabismus. ICD, OCD, PFL, and IPD were measured by digital Vernier caliper. The formula used was cIPD: 0.21+0.24 ICD+0.58°CD for males and 1.4+0.31 ICD+0.41°CD for females. Values measured by caliper were compared with that calculated by the formula. The formula used was CI: ICD × 100/OCD. Data were analyzed statistically.

RESULTS

The mean age was 6.66 ± 3.57 years. Telecanthus was the most common finding (55%). The mean ICD and OCD in males were 30.89 ± 3.33 mm and 87.96 ± 8.09 mm and in females were 30.91 ± 3.05 and 86.22 ± 6.81 mm, respectively. The mean right eye PFL in males was 28.53 ± 2.63 mm and in females was 27.66 ± 2.22 mm and left eye PFL in males was 28.53 mm ± 2.63 and in females was 27.66 ± 2.22 mm. CI in males was 35.10 ± 1.65 and in females was 35.84 ± 1.71. Mean mIPD and cIPD: male - 55.37 ± 4.75 mm and 58.56 ± 5.34 mm, female - 53.32 ± 4.74 mm and 46.26 ± 3.71 mm. A good agreement was found between mIPD and cIPD.

CONCLUSION

This study helps in documenting the anthropometric pattern of the orbitofacial parameters in children with pseudostrabismus which can act as reference data. This helps in the management of orbitofacial, craniofacial syndromes/deformities and lid reconstructive surgeries in retaining ethnical features and obtaining better function. In children's spectacle frame 1 and lens making, where measuring IPD is difficult, cIPD can be a simple alternative.

Для цитирования: Kavitha V, Mooss Vidya S, Ravishankar H N, Heralgi Mallikarjun M, Puliappadamb Haridas Mundot. Analysis of orbitofacial anthropometry in children with pseudostrabismus.. Oman journal of ophthalmology. 2023. DOI: 10.4103/ojo.ojo_326_22.