MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fbioe.2026.1846079

Медицинская библиотека · Frontiers in bioengineering and biotechnology · 2026

Mechanical behavior of functionally zoned hybrid intracranial stent integrating laser-cut and braided architectures.

Ma Lei, Li Mingxuan, Chen Maosong, Wang Dongfeng, Li Zhenqiang, Ye Gengfan, Qiao Chuan, Li Zhongyou, Lv Gen, Chen Chong, Wang Yang, Shen Daijun, Gao Ge

СтатьяПеревод пока не подготовлен

Аннотация

A novel functionally zoned hybrid intracranial stent is proposed to resolve the multifaceted mechanical limitations of existing designs by heterogeneously integrating a laser-cut anchoring segment with a braided section via interwoven filaments traversing precision-machined holes. Comprehensive finite element analysis and in vitro mechanical testing demonstrate that the optimal single-ended hybrid design simultaneously achieves five critical performance metrics: intermediate radial strength (2.89 N) between pure braided (2.12 N) and laser-cut (5.04 N) stents; comparable flexibility to braided stents (bending stiffness 0.00022 N/mm vs. 0.00023 N/mm); reduced foreshortening (18.1% vs. 22.2% and 22.0% for braided configurations); elimination of the end-constriction phenomenon through the laser-cut segment's traction effect to ensure continuous wall apposition; and preserved structural integrity during 180° bending where pure laser-cut stents fractured at 90°. Acute implantation of braided stents in rabbit subclavian arteries indirectly validates the conformability and flow-diversion capability of the braided component, confirming that this functionally zoned heterogeneous integration strategy provides a mechanically comprehensive endovascular solution for complex wide-necked intracranial aneurysms.

Для цитирования: Ma Lei, Li Mingxuan, Chen Maosong, Wang Dongfeng, Li Zhenqiang, Ye Gengfan, Qiao Chuan, Li Zhongyou, Lv Gen, Chen Chong, Wang Yang, Shen Daijun, Gao Ge. Mechanical behavior of functionally zoned hybrid intracranial stent integrating laser-cut and braided architectures.. Frontiers in bioengineering and biotechnology. 2026. DOI: 10.3389/fbioe.2026.1846079.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.