PURPOSE: To examine peripheral electroneuromyographic findings in patients with ocular pseudoexfoliation syndrome (PEX) and to compare them controls without PEX.

METHODS

A case-control study design was used to examine 31 patients with PEX and compare the findings with those of 31 age- and sex-matched healthy controls. All patients underwent complete ophthalmologic examination that included peripheral electroneuromyography examination. Motor and sensorial nerve conduction of the median, ulnar, tibial, peroneal, and sural nerve and the sympathetic skin response were measured.

RESULTS

The average sensorial nerve latency of the ulnar and sural nerve was significantly longer in the PEX group compared to the control group (p < 0.05). The average sensorial nerve conduction amplitude and the velocity of the ulnar and sural nerve were significantly lower in the PEX group (p < 0.05).

DISCUSSION: Peripheral nerves, especially sensorial fibers, appear to be affected in PEX patients. These finding may indicate that PEX is a systemic disease.

Для цитирования: Turgut Coban Deniz, Cakir Tuncay, Erol Muhammet Kazim, Dogan Gulsum, Dogan Berna, Bilgilisoy Filiz Meral, Toraman Naciye Fusun. Electroneuromyographic findings in pseudoexfoliation syndrome.. International ophthalmology. 2017. DOI: 10.1007/s10792-017-0520-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.