MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6nr01042c

Медицинская библиотека · Nanoscale · 2026

Fabrication and performance study of polyurethane-based Janus dressing with conductivity-enhanced repair, biosafety, and moist environment-promoted wound healing properties.

Luo Hang, Lin Lizhi, Feng Yongqiang, Shi Rui, Chen Yu

СтатьяПеревод пока не подготовлен

Аннотация

Polyurethane (PU) fibrous dressings face a challenge in functional modification as it is difficult to simultaneously endow them with conductivity for healing promotion, biosafety, and the ability to maintain a moist wound environment. To address this problem, we developed a strategy for constructing a Janus dressing based on a conductive PU fibrous composite. First, a conductive PU/polyaniline (PANI) network was constructed on a PU nanofibrous membrane via in situ polymerization of aniline. This network was then loaded with MXene-silver nanoparticles (AgNPs) to form a hydrophilic inner layer (PU/PANI/MXene-AgNPs). The maximum electrical conductivity of the dressing was approximately 6.5 times higher than that of PU/PANI. Subsequently, a hydrophobic PU outer layer was deposited on this hydrophilic surface via electrospinning, fabricating a Janus dressing that mimics the layered structure of skin. The Janus dressing demonstrated good biocompatibility. In vivo experiments using a rat full-thickness skin defect model confirmed its efficacy. The dressing effectively modulated inflammation, promoted collagen deposition, stimulated angiogenesis, and cell proliferation at the wound site, thereby accelerating the overall healing process. This study provides a viable approach to achieve a balance among conductive healing promotion, biosafety, and moisture management in PU-based fibrous dressings.

Для цитирования: Luo Hang, Lin Lizhi, Feng Yongqiang, Shi Rui, Chen Yu. Fabrication and performance study of polyurethane-based Janus dressing with conductivity-enhanced repair, biosafety, and moist environment-promoted wound healing properties.. Nanoscale. 2026. DOI: 10.1039/d6nr01042c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.