MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/1573405617666210114141300

Медицинская библиотека · Current medical imaging · 2021

Efficiency of Fat Suppression in T1-Weighted Inner Ear Magnetic Resonance Imaging: Multipoint Dixon Method Versus Hybrid Techniques.

Cakmak Pinar, Herek Duygu, Yagci Ahmet Baki, Sagtas Ergin, Ufuk Furkan, Çakmak Vefa

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Temporal bone is a region where fat suppression is difficult due to the inhomogeneity of various structures with different molecular properties.

INTRODUCTION

We aimed to determine the most effective fat suppression sequence in order to increase the visibility of the inner ear region.

MATERIALS AND

METHODS

The hybrid techniques and T1-Weighted mDIXON images of 40 patients with Magnetic Resonance (MR) imaging of the inner ear were prospectively compared by two experienced radiologists in terms of fat suppression efficacy. In all fat-suppressed sequences, the Signal to Noise Ratio (SNR), the spinal cord signal intensity / mean fat signal intensity ratio and spinal cord signal to noise ratio were calculated. The suppression efficacy of MR techniques for fat areas in the inner ear was visually graded.

RESULTS

Qualitative assessment of image quality due to fat suppression in the inner ear was made; the Dixon technique performed significantly better than SPAIR and SPIR techniques (p<0.0001). The mean signal intensity of the inner ear fat and SNR for the Dixon technique were significantly lower than that for SPIR and SPAIR techniques (p<0.0001). Inter-observer agreement regarding the assessment of the inner ear fat, mean signal intensity values and mean SNR values for fat suppression techniques was significant.

CONCLUSION

The Dixon technique exhibited higher image quality and fat suppression efficiency than the hybrid techniques in the MR imaging of the inner ear.

Для цитирования: Cakmak Pinar, Herek Duygu, Yagci Ahmet Baki, Sagtas Ergin, Ufuk Furkan, Çakmak Vefa. Efficiency of Fat Suppression in T1-Weighted Inner Ear Magnetic Resonance Imaging: Multipoint Dixon Method Versus Hybrid Techniques.. Current medical imaging. 2021. DOI: 10.2174/1573405617666210114141300.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.