Diagnosis of moderate-to-severe hepatic steatosis using deep learning-based automated attenuation measurements on contrast-enhanced CT.

Kim Hae Young, Lee Kyung Jin, Lee Seung Soo, Choi Se Jin, Kim Dong Hwan, Heo Subin, Jang Hyeon Ji, Choi Sang Hyun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the utility of deep learning-based automated attenuation measurements on contrast-enhanced CT (CECT) for diagnosing moderate-to-severe hepatic steatosis (HS), using histology as reference standard.

METHODS

This retrospective study included 3,620 liver donors (2,393 men and 1,227 women; mean age, 31.7 ± 9.4 years), divided into the development (n = 2,714) and test (n = 906) cohorts. Attenuation values of the liver and spleen on CECT were measured both manually and using a deep learning algorithm (before and after radiologists' correction of segmentation errors). Performance of: (1) liver attenuation and (2) liver-spleen attenuation difference for diagnosing moderate-to-severe HS (> 33%) was assessed using the area under the receiver operating characteristic curve (AUC). Three different criteria targeting 95% sensitivity, 95% specificity, and the maximum Youden's index, respectively, for diagnosing moderate-to-severe HS, were developed and validated.

RESULTS

The performance of deep learning-based measurements did not differ significantly, with or without radiologists' corrections (p = 0.13). Liver-spleen attenuation difference outperformed liver attenuation alone in diagnosing moderate-to-severe HS in both deep learning-based (AUC, 0.868 vs. 0.821; p = 0.001) and manual (AUC, 0.871 vs. 0.823; p = 0.001) measurements. In the test cohort, the criterion targeting 95% sensitivity for diagnosing moderate-to-severe HS (liver-spleen attenuation difference ≤ 2.8 HU) yielded 92.0% (69/75) sensitivity and 48.5% (403/831) specificity. The criterion targeting 95% specificity (liver-spleen attenuation difference ≤ -18.8 HU) yielded 53.3% (40/75) sensitivity and 95.7% (795/831) specificity. The criterion targeting the maximum Youden's index (liver-spleen attenuation difference ≤ -8.2 HU) yielded 82.7% (62/75) sensitivity and 80.7% (671/831) specificity.

CONCLUSION

Deep learning-based automated measurements of liver and spleen attenuation on CECT can be used reliably to detect moderate-to-severe HS.

Для цитирования: Kim Hae Young, Lee Kyung Jin, Lee Seung Soo, Choi Se Jin, Kim Dong Hwan, Heo Subin, Jang Hyeon Ji, Choi Sang Hyun. Diagnosis of moderate-to-severe hepatic steatosis using deep learning-based automated attenuation measurements on contrast-enhanced CT.. Abdominal radiology (New York). 2025. DOI: 10.1007/s00261-025-04872-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.