MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjane.2014.11.013

Медицинская библиотека · Brazilian journal of anesthesiology (Elsevier) · 2015

Comparing insertion characteristics on nasogastric tube placement by using GlideScope™ visualization vs. MacIntosh laryngoscope assistance in anaesthetized and intubated patients.

Wan Ibadullah Wan Hafsah, Yahya Nurlia, Ghazali Siti Salmah, Kamaruzaman Esa, Yong Liu Chian, Dan Adnan, Md Zain Jaafar

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

This was a prospective, randomized clinical study to compare the success rate of nasogastric tube insertion by using GlideScope™ visualization versus direct MacIntosh laryngoscope assistance in anesthetized and intubated patients.

METHODS

Ninety-six ASA I or II patients, aged 18-70 years were recruited and randomized into two groups using either technique. The time taken from insertion of the nasogastric tube from the nostril until the calculated length of tube had been inserted was recorded. The success rate of nasogastric tube insertion was evaluated in terms of successful insertion in the first attempt. Complications associated with the insertion techniques were recorded.

RESULTS

The results showed success rates of 74.5% in the GlideScope™ Group as compared to 58.3% in the MacIntosh Group (p=0.10). For the failed attempts, the nasogastric tube was successfully inserted in all cases using rescue techniques. The duration taken in the first attempt for both techniques was not statistically significant; Group A was 17.2±9.3s as compared to Group B, with a duration of 18.9±13.0s (p=0.57). A total of 33 patients developed complications during insertion of the nasogastric tube, 39.4% in Group A and 60.6% in Group B (p=0.15). The most common complications, which occurred, were coiling, followed by bleeding and kinking.

CONCLUSION

This study showed that using the GlideScope™ to facilitate nasogastric tube insertion was comparable to the use of the MacIntosh laryngoscope in terms of successful rate of insertion and complications.

Для цитирования: Wan Ibadullah Wan Hafsah, Yahya Nurlia, Ghazali Siti Salmah, Kamaruzaman Esa, Yong Liu Chian, Dan Adnan, Md Zain Jaafar. Comparing insertion characteristics on nasogastric tube placement by using GlideScope™ visualization vs. MacIntosh laryngoscope assistance in anaesthetized and intubated patients.. Brazilian journal of anesthesiology (Elsevier). 2015. DOI: 10.1016/j.bjane.2014.11.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.