MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/lbr.0000000000000651

Медицинская библиотека · Journal of bronchology & interventional pulmonology · 2020

A Randomized Controlled Trial on Optimal Sampling Sequence in Radial Guide Sheath Endobronchial Ultrasound Lung Biopsy.

Samaranayake Chinthaka B, Wright Craig, Erigadoo Shiv, Azzopardi Maree, Putt Michael, Bint Michael

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

An optimal sampling sequence in radial guide sheath endobronchial ultrasound lung biopsy (R-EBUS) is unclear. This prospective single-center pilot randomized controlled trial aimed to determine if the initial method and sequence of sampling affect the diagnostic accuracy of the procedure.

METHODS

Consecutive patients undergoing R-EBUS for lesions >15 mm with a bronchus sign were randomly assigned (1:1:1) to biopsy first (group A), brushings first (group B) or combination (group C). The primary outcome was a positive diagnosis from any sampling method.

RESULTS

Fifty-four patients were randomized. The overall diagnostic yield of the procedure was 77.8% (95% confidence interval: 66%-89%), with no difference between groups. A higher rate of positive cytology from brushings was seen if the biopsies were performed before brushings (77.8% in group A vs. 44.4% in group B, P=0.03). The rate of positive cytology from washings was higher if the washings were obtained just after the brushings (61.1% in group A vs. 11.1% in group B, P=0.02). There was no difference in the rate of positive biopsy histology in the groups (P=0.27). All 3 sampling modalities were more likely to be positive in group A (50.0% vs. 11.1% in group B and 22.2% in group C, P=0.04). Complications rate was low and not significantly different between groups.

CONCLUSION

The overall rate of a positive R-EBUS procedure was not affected by the initial sampling method or sequence. However, all 3 sampling modalities were more likely to be positive if biopsies were performed first, followed by brushings and washings.

Для цитирования: Samaranayake Chinthaka B, Wright Craig, Erigadoo Shiv, Azzopardi Maree, Putt Michael, Bint Michael. A Randomized Controlled Trial on Optimal Sampling Sequence in Radial Guide Sheath Endobronchial Ultrasound Lung Biopsy.. Journal of bronchology & interventional pulmonology. 2020. DOI: 10.1097/lbr.0000000000000651.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.