m+Medelevator.RU
← Поиск публикаций
European radiology · 2018

Fluoroscopic subtraction Eustachian tubography: initial feasibility test in a cadaver model.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kim Kun Yung, Kang Woo Seok, Park Jung-Hoon, Kang Byung-Chul, Park Jun Woo, Kim Min Tae, Bekheet Nader G, Hwang Seung Jun, Choi Joonmyeong, Cho Kyu-Jin, Park Hong Ju, Song Ho-Young

Аннотация

OBJECTIVES: To evaluate the technical feasibility of direct Eustachian tube catheterisation and subtraction Eustachian tubography in a cadaver model.

METHODS: A total of 12 separate sessions were performed on both sides of the Eustachian tube (ET) in six human cadavers. Cadavers were positioned for the submentovertical view on a fluoroscopy table. Endoscopy-guided ET selection was used in the first three cadavers, whereas fluoroscopy-guided ET selection was used in the remaining three. Eustachian tubography was performed by injecting 2 ml of contrast media through a 5-Fr catheter. We recorded the success of ET selection, number of attempts, procedure time, and tubography quality using native and subtraction images (range, 0-3).

RESULTS: Both endoscopy- and fluoroscopy-guided selections were successfully performed in five of six sessions (83.3%). There were no statistically significant differences between the endoscopy- and fluoroscopy-guided procedures in terms of the number of attempts, procedure time, rate of immediate contrast leak to the middle ear cavity, and quality of tubography (p > 0.05). An excellent quality of tubography was obtained in 83.3% (10 of 12 sessions) of subtraction images and in 33.3% (4 of 12 sessions) of native images. The tubography quality score was significantly higher for the subtraction images than for the native images (p = 0.04).

CONCLUSION: Subtraction Eustachian tubography using direct catheterisation seems to be technically feasible. The entire ET can be well visualised; thus, this technique can be used as a simple tool for assessment of ET function and anatomy.

KEY POINTS: • Direct catheterisation of the Eustachian tube is technically feasible. • The entire Eustachian tube could be well visualised by direct Eustachian tubography. • Subtraction Eustachian tubography images have better image quality than native images. • Subtraction Eustachian tubography can provide objective assessment of ET function and anatomy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты