MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.168.5.9129433

Медицинская библиотека · AJR. American journal of roentgenology · 1997

The normal anterior commissure of the glottis.

Kallmes D F, Phillips C D

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We characterized the normal width of the anterior commissure of the glottis by measuring its dimensions on CT scans obtained in patients who had no laryngeal disorders.

SUBJECTS AND

METHODS

CT scans of patients referred for cervical CT myelography were prospectively reviewed by a single board-certified radiologist. Axial images through the anterior commissure (localized by vocal process of the arytenoid cartilage, the vocal muscle, or both) were magnified on the viewing console of the CT scanner. Window and level were chosen to simulate our routine settings for CT scans of the neck. Anteroposterior width of the anterior commissure was measured using an electronic ruler with 1-mm marks.

RESULTS

Sixty-five patients were prospectively evaluated. Nine patients were excluded because of substantial motion artifact, and another 18 were excluded because CT images did not include the entire larynx. Thus, the final study group included 38 patients. The average width of the anterior commissure was 1.02 +/- 0.56 mm. The width was less than or equal to 1.1 mm in 22 (58%) of 38 patients. The width was less than or equal to 1.7 mm in 35 (92%) of 38 patients. Forty-two percent (16 of 38 patients) had anterior commissures wider than 1.0 mm. The maximum width of 2.2 mm was seen in only one patient.

CONCLUSION

The mean width of the anterior commissure was approximately 1.0 mm. However, 42% of patients had anterior commissures wider than 1.0 mm. In our series, using an upper limit of 1.6 mm as a normal measurement for the anterior commissure would have included 92% of patients, and an upper limit of 2.1 mm would have encompassed the mean plus two SDs.

Для цитирования: Kallmes D F, Phillips C D. The normal anterior commissure of the glottis.. AJR. American journal of roentgenology. 1997. DOI: 10.2214/ajr.168.5.9129433.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.