Clinical implant dentistry and related research · 2013
Nongrafted sinus floor elevation with a space-maintaining titanium mesh: case-series study on four patients.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Atef Mohammed, Hakam Maha Mohammed, ElFaramawey Mohamed Ibrahim, Abou-ElFetouh Adel, Ekram Mohamed
Аннотация
PURPOSE: Numerous materials and techniques have been introduced to augment the maxillary sinus floor for future dental implant placement. Schneiderian membrane tenting above simultaneously placed implants proved to be a successful technique. The present study investigated the use of a titanium micromesh for lateral-window sinus floor elevation without bone grafting.
MATERIAL AND METHODS: Four patients indicated for two-stage sinus lifting were included. Through a lateral window, a titanium micromesh was tailored and placed into the sinus to maintain the elevated membrane in place. Immediate and 6-month postoperative cone beam computed tomography (CBCT) was performed to measure the gained bone height. During implant placement, bone core biopsies were retrieved for histomorphometry.
RESULTS: The average residual ridge height among the eight sinuses was 3.6 mm ± 1.6 mm. Six months postoperatively, it reached 9.63 mm ± 1.47 mm. Histomorphometry revealed that the average bone volume of the native bone was 30.3% ± 9.1%, while that of the newly formed bone was 55.3% ± 11.4%.
CONCLUSION: Within the limitations of this study due to the small sample size, the use of the titanium micromesh as a space-maintaining device after schneiderian membrane elevation is a reliable technique to elevate the floor of the sinus without grafting.
MATERIAL AND METHODS: Four patients indicated for two-stage sinus lifting were included. Through a lateral window, a titanium micromesh was tailored and placed into the sinus to maintain the elevated membrane in place. Immediate and 6-month postoperative cone beam computed tomography (CBCT) was performed to measure the gained bone height. During implant placement, bone core biopsies were retrieved for histomorphometry.
RESULTS: The average residual ridge height among the eight sinuses was 3.6 mm ± 1.6 mm. Six months postoperatively, it reached 9.63 mm ± 1.47 mm. Histomorphometry revealed that the average bone volume of the native bone was 30.3% ± 9.1%, while that of the newly formed bone was 55.3% ± 11.4%.
CONCLUSION: Within the limitations of this study due to the small sample size, the use of the titanium micromesh as a space-maintaining device after schneiderian membrane elevation is a reliable technique to elevate the floor of the sinus without grafting.
Предметные рубрики MeSH
AdolescentAdultAlveolar ProcessBiocompatible MaterialsBiopsyBone RegenerationCone-Beam Computed TomographyDental Implantation, EndosseousDental ImplantsDental Prosthesis, Implant-SupportedFemaleFollow-Up StudiesHumansMaleMaxillaMaxillary SinusMiddle AgedNasal MucosaOsteogenesisSinus Floor AugmentationSurgical MeshTitanium