Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association · 2009
Short 5Fr vs long 3Fr pancreatic stents in patients at risk for post-endoscopic retrograde cholangiopancreatography pancreatitis.
СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chahal Prabhleen, Tarnasky Paul R, Petersen Bret T, Topazian Mark D, Levy Michael J, Gostout Christopher J, Baron Todd H
Аннотация
BACKGROUND & AIMS: Prophylactic placement of pancreatic duct (PD) stents reduces the risk of post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) in high-risk patients. Some endoscopists prefer longer length, unflanged 3Fr PD stents because they are supposedly more effective and have a higher rate of spontaneous dislodgement; we compared outcomes of patients with these 2 types of stents.
METHODS: Patients at high risk for PEP were randomly assigned to groups given either a straight, 5Fr, 3 cm long, unflanged PD stent (n = 116) or a 3Fr, 8 cm or longer, unflanged PD stent (n = 133). Abdominal radiographs were obtained at 24 hours, 7 days, and 14 days following stent placement to assess spontaneous stent dislodgement. PEP was defined according to consensus criteria.
RESULTS: After 14 days, the spontaneous stent dislodgement rates were 98% for 5Fr stents and 88% for 3Fr stents (P = .0001). PEP occurred in 12% of patients. The incidence of PEP was higher in the 3Fr group (14%) than the 5Fr group (9%), although this difference was not statistically significant (P = .3). Placement failure did not occur in any patients in the 5Fr stent group, but did occur in 11 of the 133 patients in the 3Fr stent group (P = .0003).
CONCLUSIONS: Among patients at high-risk for PEP, the spontaneous dislodgement rate of unflanged, short-length, 5Fr PD stents is significantly higher than for unflanged, long-length, 3Fr stents. This decreases the need for endoscopic removal. A higher rate of PD stent placement failure and PEP was observed in patients with 3Fr stents. To view this article's video abstract, go to the AGA's YouTube Channel.
METHODS: Patients at high risk for PEP were randomly assigned to groups given either a straight, 5Fr, 3 cm long, unflanged PD stent (n = 116) or a 3Fr, 8 cm or longer, unflanged PD stent (n = 133). Abdominal radiographs were obtained at 24 hours, 7 days, and 14 days following stent placement to assess spontaneous stent dislodgement. PEP was defined according to consensus criteria.
RESULTS: After 14 days, the spontaneous stent dislodgement rates were 98% for 5Fr stents and 88% for 3Fr stents (P = .0001). PEP occurred in 12% of patients. The incidence of PEP was higher in the 3Fr group (14%) than the 5Fr group (9%), although this difference was not statistically significant (P = .3). Placement failure did not occur in any patients in the 5Fr stent group, but did occur in 11 of the 133 patients in the 3Fr stent group (P = .0003).
CONCLUSIONS: Among patients at high-risk for PEP, the spontaneous dislodgement rate of unflanged, short-length, 5Fr PD stents is significantly higher than for unflanged, long-length, 3Fr stents. This decreases the need for endoscopic removal. A higher rate of PD stent placement failure and PEP was observed in patients with 3Fr stents. To view this article's video abstract, go to the AGA's YouTube Channel.