MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/clr.12071

Медицинская библиотека · Clinical oral implants research · 2012

Primary implant stability in the atrophic sinus floor of human cadaver maxillae: impact of residual ridge height, bone density, and implant diameter.

Pommer Bernhard, Hof Markus, Fädler Andrea, Gahleitner André, Watzek Georg, Watzak Georg

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Simultaneous implant placement in conjunction with lateral or transcrestal maxillary sinus floor augmentation gives the benefit of reduction in healing times and surgical interventions. Primary implant stability, however, may be significantly reduced in resorbed residual ridges. Aim of the present study was to investigate the impact of residual bone height, bone density, and implant diameter on primary stability of implants in the atrophic sinus floor.

MATERIAL AND

METHODS

A total of 66 NobelActive implants were inserted in the sinus floor of fresh human cadaver maxillae: 22 narrow (3.5 mm), 22 regular (4.3 mm), and 22 wide (5.0 mm) diameter implants in residual ridges of 2-6 mm height. Presurgical computed tomographic scans were acquired to assess bone height and density. Primary implant stability was evaluated by insertion torque values (ITV), Periotest values (PTV), and Osstell implant stability quotients (ISQ).

RESULTS

Correlations within outcomes (ITV, PTV, ISQ) were highly significant (P < 0.001). Radiographic bone density was found to significantly impact all three outcome measures (P < 0.001), while no influence of residual bone height and implant diameter could be revealed by multifactorial analysis. Consistent results were seen in all subgroups (including residual ridges of 5-6 mm height).

CONCLUSIONS

Bone density seems to represent the major determinant of primary stability in maxillary sinus augmentation with simultaneous implant placement (as well as 5-6 mm short implants in the maxillary sinus floor). Preoperative bone density assessment may help to avoid stability-related complications in one-stage implant treatment of the atrophic posterior maxilla.

Для цитирования: Pommer Bernhard, Hof Markus, Fädler Andrea, Gahleitner André, Watzek Georg, Watzak Georg. Primary implant stability in the atrophic sinus floor of human cadaver maxillae: impact of residual ridge height, bone density, and implant diameter.. Clinical oral implants research. 2012. DOI: 10.1111/clr.12071.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.